FIRE AND EXPLOSION HAZARD
Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and
result in fire or explosion and serious injury.
D Ground the equipment and the object being sprayed. See Grounding on page 5.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvent or the fluid being
sprayed.
D Extinguish all the open flames or pilot lights in the spray area.
D Electrically disconnect all the equipment in the spray area.
D Keep the spray area free of debris, including solvent, rags, and gasoline.
D Do not turn on or off any light switch in the spray area while operating or if fumes are present.
D Do not smoke in the spray area.
D Do not operate a gasoline engine in the spray area.
D If there is any static sparking while using the equipment, stop spraying immediately. Identify and
correct the problem.
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result
INSTRUCTIONS
in a serious injury.
D This equipment is for professional use only.
D Read all the instruction manuals, tags, and labels before operating the equipment.
D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco
distributor.
D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
D Check the equipment daily. Repair or replace worn or damaged parts immediately.
D Do not exceed the maximum working pressure of the lowest rated system component. These
dispensing valves have a 3000 psi (21.0 MPa, 210 bar) Maximum Working Pressure.
D Use fluids that are compatible with the equipment wetted parts. See the Technical Data section of
all the equipment manuals. Read the fluid manufacturer's warnings.
D Route the hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not
expose Graco hoses to temperatures above 180_F (82_C) or below –40_F (–40_C).
D Wear hearing protection when operating this equipment.
D Comply with all applicable local, state, and national fire, electrical, and other safety regulations.
MOVING PARTS HAZARD
Moving parts, such as the air motor piston, can pinch or amputate fingers.
D Keep clear of all moving parts when starting or operating the pump.
D Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the
equipment.