6
Pin No.
1
NC (Not connected)
2
RXD
3
TXD
4
Non Use
5
GND (Ground)
6
Non Use
7
RTS
8
CTS
9
NC (Not connected)
These signal names are those of computer
specifications.
Communication parameters
Signal level: RS-232C compliant
Synchronization method: Asynchronous
Baud rate: 9 600 bps
Parity: None
Character length: 8 bits
Stop bit: 1 bit
Flow control: None
Basic format for control data
The transmission of control data from the computer
starts with a STX signal, followed by the command, the
parameters, and lastly an ETX signal in that order. Add
parameters as required according to control details.
STX
C1 C2
C3
Start
3-Character
Command
(3 Bytes)
English - 36 -
2
3
4
5
8
7
9
Signal Name
Shorted in this set
:
P1 P2 P3 P4 P5
Colon
Parameter(s)
Command
PON
POF
AVL
AMT
IMS
DAM
Note:
If multiple commands are transmitted, be sure
to wait for the response for the first command
to come from this unit before sending the next
command.
If an incorrect command is sent by mistake, this
unit will send an "ER401" command back to the
computer.
When sending a command which does not
require parameter, a colon (:) is not needed.
Consult your local Panasonic dealer for detail
instructions on command usage.
For more details, visit the following web site.
ETX
https://panasonic.net/cns/prodisplays/
End
Parameter
Control Details
None
Power ON
None
Power OFF
***
Volume 000-100
0
Audio MUTE OFF
1
Audio MUTE ON
None
Input Select (toggle)
HM1
HDMI1
HM2
HDMI2
HM3
HDMI3
HM4
HDMI4
DP1
DisplayPort
SL1
PC1
UC1
USB- C
WD1
Wireless Display
Aspect mode select
AUTO
FULL
1609
1409
0403
CINM
Cinema
SLOT
PC
Auto
Full
16:9
14:9
4:3