SERVICE continued
The following is a guide of the menu options available on screen accessed by pressing the Menu button. Certain
menu selections, which are marked by an asterisk ( * ), may or may not be present depending on other menu settings.
TEST MODE
(stays on for 30 minutes)
Test Mode
Blower (Non-VS)
Blower (VS)
Cooling
Comp Heating*
Indoor Heating
Aux Relay
Once testing is complete, press the Done button to exit and return to menu.
REMINDERS
Setting
Filtration Enable
Filter Period*
Start Month*
System Maint Enable
Maint Period*
First Maint Month*
Second Maint Month*
Humidifier Enable
Start Month
Once all selections have been made, press the Done button to exit and return to menu. Press Next to navigate to the next setting.
RESTORE DEFAULTS
Setting
Restore HVAC Defaults
Restore Factory Defaults
ABOUT
Setting
Version
Device ID (SIN)
ODU Type
IDU Type
SOV
Once all selections have been made, press the Done button to exit and return to menu. Press Next to navigate to the next setting.
8
XR724 USER GUIDE
Settings
Blower On
50%, 100%
Single Stage, 1st Stage, 2nd Stage
Single Stage, 1st Stage, 2nd Stage
Single Stage, 1st Stage, 2nd Stage
Relay On
Range
[No], Yes
[Monthly], Quarterly, Bi-Annually,
Annually
[Jan], Feb, Mar, Apr, May, Jun,
Jul, Aug, Sep, Oct, Nov, Dec
[No], Yes
[Bi-Annually], Annually
Jan, Feb, [Mar], Apr, May, Jun,
Jul, Aug, Sep, Oct, Nov, Dec
Jan, Feb, Mar, Apr, May, Jun, Jul,
Aug, [Sep], Oct, Nov, Dec
[Yes], No
[Jan], Feb, Mar, Apr, May, Jun,
Jul, Aug, Sep, Oct, Nov, Dec
Action
Yes, No
Press and Hold "Yes"
Range
XXXXXX
XXXXXX
None, AC, HP
Electric, Gas/Oil, Hydronic
W/Cool, W/Heat
Energize "G" circuit
Energize "G" and "BK" circuit
Energize selected "Y1" or "Y2", "O" and "G" circuit (BK also for VS
indoor unit)
Energize selected "Y1" or "Y2" and "G" circuit ("BK" also for VS
indoor unit)
Energize selected "W1" or "W2" ("G" circuit also for electric heat)
Close normally open dry contacts
Filter change reminder
Filter change reminder period
Period start month
System Maintenance reminder
Maintenance reminder period
Period start month
2nd period start month
Resets all HVAC settings to Default Settings
Press and hold "Yes" button until "Factory" is displayed
Resets HVAC and WiFi defaults
Firmware version number
Unit serial number
Outdoor unit type setting
Indoor unit type setting
Switchover value type setting (HP only)
Description
Description
Description
Description
18-HD82D1-1B-EN