Carrier 53SSA009 1 Series Service Manual page 11

Portable, split
Table of Contents

Advertisement

7
UNIT DISASSEMBLY
Remove the pipe conduit plate releasing the six plastic
tabs which secure it to the unit.
Fan motor replacement
Disconnect the polarized electronic connector and TH sensor.
Using a screwdriver release the four plastic tabs that keep
the half scroll of the fan in place.
In this way it is possible to extract the motor from the
rubber vibration isolators which are supporting it.
If one or more plastic tabs of the half scroll of the fan are
broken, the half scroll can be secured by similar screws to
the ones used in the unit, during the re-assembly.
Coil removal
Remove the air flow flap and its holder.
Extract the refrigerant from the unit using a suitable
device and avoiding to exhaust it in the atmosphere.
Unsolder and disconnect coil piping and then remove it.