10.1.5.2. Handset
Does Handset link with Base Unit?
(Properly working unit)
NO
Is the voltage of TP VBAT about 2.2~2.8 V?
YES
Is the voltage of TP VDDC about 1.2 V?
YES
Is the voltage of TP 3.0 V about 3.0 V?
YES
Does the RF clock (CLK) oscillate: 13.824 MHz
in Handset Test Mode?
YES
Check the RF part
Cross Reference:
Power Supply Circuit/Reset Circuit (P.23)
Check the RF part (P.42)
Note:
Refer to Things to Do after Replacing IC or X'tal (P.60)(P.69) for Handset.
*1 How to adjust the frequency of X1:
To see the frequency, execute the command "SFR", then check the TP_CKM (IC1-57pin).
To adjust frequency, send command "SFR
KX-TGF340/KX-TGF342/KX-TGF343/KX-TGF344/KX-TGF345/KX-TGF372/KX-TGF373/KX-TGF374/KX-TGF375/KX-TG585/KX-TGFA30
YES
NO
NO
NO
"until the frequency counter becomes13.824 MHz±55HZ.
Handset is OK. Check Base Unit.
Check the batteries.
Check around Power Supply Circuit/Reset Circuit.
Check around X1 and RF module and adjust
clock frequency.
*1