Settings On The Base Screen (Using Shortcut Keys); Display Switching Mode - Panasonic HG-T Series User Manual

Thru-beam type digital displacement sensor
Hide thumbs Also See for HG-T Series:
Table of Contents

Advertisement

5.5 Settings on the Base Screen (Using Shortcut Keys)

5.5 Settings on the Base Screen (Using Shortcut Keys)

This section explains other functions that can be used from the base screen.

5.5.1 Display Switching Mode

Overview
You can change the display of the digital display section / SUB (green) as needed for the task.
For example, if you select "Sensor head measured value", the actually measured value and
judgment value can be simultaneously compared and displayed, making it easy to check the
state of sensor head measurement.
Settings
Name
Normal measured
1
value
Calculated
2
(Note 1)
value
3
Label
4
LOW set value
5
HIGH set value
5-30
Digital
display
section
SUB (Green)
Shows the normal measured value.
● When using the hold function, you can check
internal measured values that are not held.
Shows the calculated value.
● When using the calculation function and hold
function, you can check calculation results that
are not held.
You can view and set any values or characters.
● This saves you the trouble of attaching sensor
number and other labels on the controller.
Shows the LOW set value.
● You can check the judgment value and lower limit
value at the same time.
Shows the HIGH set value.
Description
Factory
default
state
Default state
-
-
-
-
WUME-HGT-6