Download Print this page
Whirlpool LTE5243D Product Dimensions
Whirlpool LTE5243D Product Dimensions

Whirlpool LTE5243D Product Dimensions

24" (61 cm) electric washer/dryer

Advertisement

®
PRODUCT MODEL NUMBER
LTE5243D
Electrical: A three- or four-wire, single-phase,
120/240-volt, 60-Hz, AC-only electrical supply (or
three- or four-wire, 120/208-volt electrical supply,
if specified on the serial/rating plate) on a separate
30-amp circuit, fused on both sides of the line
must be provided. A time-delay fuse or circuit
breaker is recommended. Connect to an individual
branch circuit. Do not have a fuse in the neutral or
grounding circuit. Do not use an extension cord.
Exhaust venting: Exhaust your dryer to the
outside. Use a heavy metal vent. Do not use plastic
or metal foil vent. 4" (102 mm) heavy metal
exhaust vent and clamps must be used.
DURASAFE™ venting products are recommended.
Exhaust outlet hood must be at least 12" (30.5 cm)
from the ground or any object that may be in the
path of the exhaust. The dryer can be converted to
exhaust out right or left side.
EXHAUST VENTING
Select the route that will provide the straightest and most
direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. Use the fewest 90° turns
possible.
Do not use vent runs longer than specified in vent length
chart.
Determine the number of elbows you will need.
Recommended hood styles
B
A
Angled hood style
4"
(10.2 cm)
4"
(10.2 cm)
(10.2 cm)
A . Louvered hood style
B . Box hood style
Vent Length Chart
No. of
Type of Vent
Box or
90° turns
Louvered
or elbows
hoods
0
Rigid metal
43 ft (13.1 m)
1
Rigid metal
33 ft (10.1 m)
2
Rigid metal
23 ft (7.0 m)
NOTE: Side exhaust adds a 90° turn inside the washer/dryer. To
determine maximum exhaust length, add one 90° turn to the
chart.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
24" (61 cm) Electric Washer/Dryer
PRODUCT DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are
required. Louvered doors with equivalent ventilation openings are acceptable.
is acceptable.
4"
**Rear clearance may be 0" (0 cm) when house exhaust system is lined up directly with dryer exhaust.
2.5"
(6.4 cm)
DRAIN SYSTEM
Standpipe drain system - wall or floor
Angled
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away
hoods
capacity can be no less than 17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm) diameter
standpipe adapter kit is available.
36 ft (11.0 m)
The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (2.4 m) from the bottom
of the washer.
26 ft (7.9 m)
Laundry tub drain system
16 ft (4.9 m)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 34"
(86.4 cm) above the floor and no higher than 96" (2.4 m) from the bottom of the washer.
Floor drain system
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses
might be needed.
3
15 "
(39.1 cm)
71 ¾"
(182.2 cm)
*27 ¼"
(69.2 cm)
1"
23 "
1"
7
8
(2.5 cm)
(60.6 cm)
(2.5 cm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
8
32 "
1
8
(81.6 cm)
* Most installations require a
minimum 5" (12.7 cm)
clearance behind the dryer for
the exhaust vent with elbow.
23 "
7
8
(60.6 cm)
1"
(2.5 cm)
2
48 in.
2
(310 cm
)
2
24 in.
2
(155 cm
)
5"**
1"*
27¼"
(2.5 cm)
(12.7 cm)
(69.2 cm)
B
3" (7.6 cm)
3" (7.6 cm)
C
Ref. W10222387
10-31-08

Advertisement

loading