A1500SP1
User's Manual
PRODUCT REGISTRATION
Thank you for purchasing a CyberPower product. Please take a few minutes to register your product in Registration section at
CyberPowerSystems.com/registration. Registration certifies your product's warranty, confirms your ownership in the event of a product loss or
theft and entitles you to free technical support. Register your product now to receive the benefits of CyberPower ownership.
IMPORTANT SAFETY INSTRUCTIONS
(SAVE THESE INSTRUCTIONS)
This Manual Contains Important Instructions that should be followed during Installation and Maintenance of the UPS and batteries.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants.
(Please see specifications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before servicing
the batteries. There are no user serviceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded.
If you need to de-energize this equipment, turn off and unplug the unit.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery.
CAUTION! Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment,
ANSI/NFPA 75.
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in
accordance with the National Electric Code, ANSI/NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
applications. DO NOT use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or patient
care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from
the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation such as
airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
INSTALLING YOUR UPS SYSTEM
INTRODUCTION
Thank you for selecting a CyberPower Systems Uninterruptible Power Supply (UPS) product. This UPS is designed to provide unsurpassed power
protection, operation and performance during the lifetime of the product.
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(a) UPS (b) User's manual (c) USB A+B type cable (d) Function Setup Guide
OVERVIEW
The A1500SP1 provides complete power protection from utility power that is not always
consistent.
The A1500SP1 features 1500 Joules of surge protection.
The unit ensures consistent power to your sump pump and provides long lasting battery
backup during power outages with maintenance free batteries.
AUTOMATIC VOLTAGE REGULATOR
The A1500SP1 stabilizes inconsistent utility power voltage to consistent and safe 110/120 volts without
switching to battery backup power. This help to reserve the battery for when it's needed most during a
blackout.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the
battery's maximum charge capacity, it is recommended that you charge the battery for at least 8 hours.
Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge whether the
UPS is turned on or off.
2. Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment.
The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up.
3. Elevate the UPS at least 18 inches above the floor on a stable surface like a table or shelf.
4. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
5. With the UPS unit turned off and unplugged, connect your sump pump into the battery power supplied outlet closest to the top of the unit. This unit
1
/
will work with sump pumps up to
HP in size. DO NOT plug any additional equipment into the UPS, as any additional power demands
2
may overload and damage the UPS.
6.
Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker
and does not service equipment with large electrical demands (e.g. air conditioner, copier, etc...).
The warranty prohibits the use of extension cords, outlet strips, and surge strips.
7. Press the power switch to turn the unit on. The Power On indicator light will illuminate and the unit will "beep".
If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the
UPS off and ensure that the sump pump is no large than
the unit. Make sure the circuit breaker is depressed and then turn the UPS on.
8. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
9. To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every three
months to ensure battery life.
BASIC OPERATION
DESCRIPTION
1.
Power Switch
Used as the master on/off switch for equipment connected to the battery power supplied outlets. (Please refer to the Function Setup Guide
for more information.)
2.
Power On Indicator
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
3.
LCD module display
The LCD display shows all the UPS information using icons and messages. For more information please review the "Definitions for Illuminated
LCD Indicators" section below.
4. Display/Select Button
1
/
HP in size and that no other devices are plugged into
2
The button can be used to select the LCD display contents including Input Voltage, and output Voltage. Short press the button to scroll down the
function menu. Pressing the button for 3 seconds will keep the LCD display always on or turn the LCD display off while in AC/Utility power mode.
(Please refer to the Function Setup Guide for more information.)
5.
Mute/Enter Button
Holding the button for more than 3 seconds will silence the alarm. Short press the ENTER button to confirm the setting. After the setting has
K01-0000897-00
been confirmed, the LCD screen will stop flashing. (Please refer to the Function Setup Guide for more information.)
6.
Battery and Surge Protected Outlets
The UPS has battery powered/surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your sump
pump during a power failure. (DO NOT plug any additional devices into the "Battery and Surge Protected Outlets". The power demands
of these devices may overload and damage the unit.)
7.
Full-Time Surge Protection Outlets
The UPS has surge suppression outlets.
8.
Circuit Breaker
Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection.
9.
Serial/USB Ports to PC
The USB port allows connection and communication between the USB port on the computer and the UPS unit.
10. Communication Protection Ports
Communication protection ports, bi-directional, will protect a 10/100/1000 Ethernet connection (RJ45).
11. Wiring Fault Indicator (red)
This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring. If this is
illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The UPS will not provide
surge protection without being plugged into a grounded and properly wired wall outlet.
12. Coax/Cable/DSS Surge Protection
The Coax/Cable/DSS protection ports will protect any cable modem, CATV converter, or DSS receiver.
13. Outlets Designed for AC Adapters
The unit has two outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets.
REPLACING THE BATTERY
Replacement of batteries located in an OPERATOR ACCESS AREA.
1.
When replacing batteries, replace with the same number of the following battery: CyberPower / RB1290X2 for A1500SP1.
2.
CAUTION! Risk of Energy Hazard, maximum 24V 9 Ampere-hour battery for A1500SP1. Before replacing batteries, remove conductive
jewelry such as chains, wrist watches, and rings. High energy conducted through these materials could cause severe burns.
3.
CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
4.
CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic.
5.
CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when
working on batteries:
(1) Remove watches rings, or other metal objects.
(2) Use tools with insulated handles.
CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO
LOCAL REGULATIONS.
BATTERY REPLACEMENT PROCEDURE:
A1500SP1
1.
Turn off and unplug all connected equipment.
Plug in
2.
Turn the UPS off and unplug it from the AC power source.
3.
Turn the UPS on its side.
4.
Remove the front panel retaining screws located on the bottom of the UPS.
5.
Slide the battery compartment cover (front panel) completely off of the unit.
6.
Disconnect the battery wires from the batteries.
7.
Remove the batteries from the compartment.
8.
Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors from both the upper and lower
battery pack. Note: Only use new batteries for replacement and both batteries should be replaced at the same time to ensure maximum life
span.
9.
Put the batteries back into the compartment.
10.
Slide back the battery compartment cover and tighten the retaining screws.
11.
Recharge the UPS for 8-16 hours to fully charge the battery.
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
1.
INPUT voltage meter:
This meter measures the AC voltage that the UPS system is receiving from the utility wall outlet. The UPS is designed, through the use of
automatic voltage regulation, to continuously correct output voltage to connected equipment to a safe 120 voltage output range. In the event of
a complete power loss, severe brownout, or over-voltage, the UPS relies on its internal battery to supply consistent 110/120 output voltage.
The INPUT voltage meter can be used as a diagnostic tool to identify poor-quality input power.
2.
OUTPUT voltage meter:
This meter measures, in real time, the AC voltage that the UPS system is providing to the computer, such as normal line mode, AVR mode,
and battery backup mode. (Note: The OUTPUT voltage meter shows the status of the battery backup outlets.)
3.
ESTIMATED RUN TIME:
This displays the run time estimate of the UPS with current battery capacity and load.
4.
NORMAL icon:
This icon appears when the UPS is working under normal conditions.
5.
BATTERY icon:
During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to indicate the UPS is
operating from its internal batteries. During a prolonged brownout or blackout, the alarm will sound continuously to indicate the UPS's batteries
are nearly out of power. You should save files and turn off your equipment immediately or allow the software to shut the system down.
6.
AVR (Automatic Voltage Regulation) icon:
This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power. This is a normal, automatic
operation of your UPS, and no action is required on your part.
7.
SILENT MODE icon:
This icon appears whenever the UPS is in silent mode.
8.
OVER LOAD icon:
This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload, unplug some of your
equipment from the battery-supplied outlets until the icon turns off and the alarm stops.
9.
FAULT icon:
This icon appears if there is a problem with the UPS, Contact CyberPower Systems at for further help and support.
E01: Charger Fault – Overcharge (Contact CyberPower Systems for support.)
E02: Charger Fault – No Charge (Contact CyberPower Systems for support.)
E21: Battery Output Short Fault (Turn on the UPS again.)
E22: Battery Mode or AC/Utility Power Mode Overload Fault (Unplug at least one piece of equipment from battery outlets and turn the UPS
on again.)
10.
BATT. CAPACITY meter:
This meter displays the approximate charge level (in 20% increments) of the UPS's internal battery. During a blackout or severe brownout, the
UPS switches to battery power, the BATTERY icon appears, and the charge level decreases.
11.
LOAD CAPACITY meter:
This meter displays the approximate output load level (in 20% increments) of the UPS battery outlets.
For more information about functions setup, please refer to the Function Setup Guide.
E11: Battery Overvoltage (Contact CyberPower Systems for support.)

Advertisement

loading

Summary of Contents for CyberPower A1500SP1 Series

  • Page 1 (DO NOT plug any additional devices into the “Battery and Surge Protected Outlets”. The power demands Thank you for purchasing a CyberPower product. Please take a few minutes to register your product in Registration section at CyberPowerSystems.com/registration.
  • Page 2 The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty. For further information please feel free to contact CyberPower at Cyber Power Systems (USA), Inc. 4241 12 Ave E., STE 400, Shakopee, MN 55379;...