Mitsubishi Electric FR-E700 Series Instruction Manual page 283

Hide thumbs Also See for FR-E700 Series:
Table of Contents

Advertisement

Parameter
Monitor description list (Pr. 52)
● Set the monitor to be displayed on the operation panel and parameter unit (FR-PU04/FR-PU07)
in Pr. 52 "DU/PU main display data selection".
● Set the monitor to be output to the terminal AM (analog output (0 to 10V DC voltage output)) in
Pr. 158 "AM terminal function selection".
Types of Monitor
Output frequency
Output current
Output voltage
Alarm display
Frequency setting
Motor torque
Converter output voltage
Regenerative brake duty
Electronic thermal relay
function load factor
Output current peak value
Converter output voltage
peak value
Output power
Input terminal status
Output terminal status
Cumulative
energization time
Reference voltage output
Tab.6-35:
Monitor description list (1)
FR-E700SC EC
Pr. 52
Opera-
Unit
tion
PU Main
Panel
Monitor
LED
0.01Hz
0/100
0.01A/0.1A
0/100
0.1V
0/100
0/100
0.01Hz
5
0.1%
7
0.1V
8
0.1%
9
0.1%
10
0.01A
11
0.1V
12
0.01kW
14
1h
20
Monitor display and monitor output signals
Pr. 158 (AM)
Terminal AM
Setting
Full Scale Value
1
Pr. 55
2
Pr. 56
200V class
400V
3
400V class
800V
5
Pr. 55
Rated torque of the
7
applied motor × 2
200V class
400V
8
400V class
800V
9
Pr. 70
10
100%
11
Pr. 56
200V class
400V
12
400V class
800V
Rated inverter
14
power × 2
21
Description
Displays the inverter output frequency.
Displays the inverter output current
effective value.
Displays the inverter output voltage.
Displays 8 past alarms individually.
Displays the set frequency.
Displays the motor torque in % on the
assumption that the rated motor
torque is 100%.
(Displays 0% during V/F control)
Displays the DC bus voltage value.
Brake duty set in Pr. 30, Pr. 70
Displays the motor thermal cumulative
value on the assumption that the ther-
mal operation level is 100%.
Holds and displays the peak value of
the output power monitor.
(Cleared at every start)
Holds and displays the peak value of
the DC bus voltage value.
(Cleared at every start)
Displays the power on the inverter out-
put side
Displays the input terminal ON/OFF sta-
tus on the PU.
(Refer to page 6-143 for DU display.)
Displays the output terminal ON/OFF
status on the PU.
(Refer to page 6-143 for DU display.)
Adds up and displays the energization
time after inverter shipment.
You can check the numbers of the
monitor value exceeded 65535h with
Pr. 563.
Terminal AM: Output 10V
6 - 139