Appendix LCD Messages

There are 3 types of LCD messages:
E : Error messages
I : Informational messages
S : Status messages
LCD Message
At BOD
At EOD
Bad Media
Cannot Write
Non-MRS Tape
Clean fail:
Check Cleaning
Tape
Clean Me
Cleaning
Close Door
Drive Comms
Error
Drive fault
22
Type
Light Status
E
On
E
On
E
Flashing
E
Flashing
E
Flashing
E
Flashing
S
E
Flashing
E
On
E
Meaning
A SPACE command encountered an unexpected
BOD (Beginning of Data).
The tape is now positioned at the BOD.
A READ or SPACE command encountered an unex-
pected EOD (End of Data).
The tape is now positioned at the EOD.
A READ or SPACE command has failed because
the tape is not in DDS format.
Action: Unload the tape and use a DDS-certified
(Media Recognition System) tape.
A WRITE, WRITE FILEMARK or ERASE command
has been attempted on a non-Media Recognition
System tape.
Action: Remove the cartridge and replace it with a
Media Recognition System cartridge.
Cleaning failed, possibly due to an expired tape.
Action: Use a new cleaning cartridge.
A high error rate has been detected while reading or
writing.
Action: Insert a cleaning cartridge to clean the tape
heads, ensuring that the tape in the cleaning car-
tridge has not been used up.
A cleaning cartridge has been loaded into the drive
mechanism.
The autoloader does not work because the front
panel door is open.
Action: This is probably caused by a magazine that
is not fully inserted into the autoloader. Insert the
magazine fully into the autoloader or remove it.
The drive has stopped communicating with the
changer mechanism.
Action: Call for service.
The drive has detected an internal error.