10.3
Setting the maximum heating output
The product's maximum heating output is set to automatic
mode at the factory. If you want to set your own fixed max-
imum heating output, however, you can specify a value un-
der d.00 which equates to the product output in kW.
10.4
Setting the maintenance interval
If you set the maintenance interval, after a configurable num-
ber of burner operating hours, the message that the product
must be serviced appears in the display, together with the
maintenance symbol
.
▶
Use diagnostics code d.84 to set the number of operating
hours until the next maintenance is due (number of op-
erating hours = display value x 10). Guideline values can
be found in the following table.
Guideline value for burner
operating hours until the
Number
next inspection/maintenance
Heat de-
of per-
work is due for an average
mand
sons
operating time of one year
(dependent upon the system
type)
1 ‑ 2
1050 h
5.0 kW
2 ‑ 3
1150 h
1 ‑ 2
1500 h
10.0 kW
2 ‑ 3
1600 h
2 ‑ 3
1800 h
15.0 kW
3 ‑ 4
1900 h
3 ‑ 4
2600 h
20.0 kW
4 ‑ 5
2700 h
3 ‑ 4
2800 h
25.0 kW
4 ‑ 6
2900 h
3 ‑ 4
3000 h
> 27.0 kW
4 ‑ 6
3000 h
The values stated correspond to an average operating time
of one year.
If you do not set a numerical value but do set the symbol
"– – –", the function is not active.
Note
On completion of the set operating hours, you
must set the maintenance interval again.
10.5
Setting the pump output
Validity: VUW 246/7-2 (H-GB)
OR VUW 286/7-2 (H-GB)
OR VUW 346/7-2 (H-GB)
The product is equipped with a speed-regulated high-effi-
ciency pump, which adjusts independently to the hydraulic
conditions of the heating installation.
If you have installed a low loss header in the heating install-
ation, we recommend switching off the speed regulation and
setting the pump output to a fixed value.
▶
If required, change the setting of the pump speed, which
depends on the operating mode, under diagnostics code
d.14.
0020253094_05 ecoTEC sustain Installation and maintenance instructions
Remaining feed head of the pump
Pump curve
Validity: VUW 246/7-2 (H-GB)
OR VUW 286/7-2 (H-GB)
B
1
2
3
40
35
30
25
20
15
10
5
0
0
500
1
PWM 65%
2
PWM 73%
3
PWM 80%
4
PWM 88%
5
PWM 95 to 100%
Pump curve
Validity: VUW 346/7-2 (H-GB)
B
1
2
3
40
35
30
25
20
15
10
5
0
0
500
1
PWM 65%
2
PWM 73%
3
PWM 80%
4
PWM 88%
5
PWM 95 to 100%
10.6
Setting the bypass
Caution.
Risk of material damage caused by incor-
rect setting of the high-efficiency pump
If the pressure at the bypass is increased (by
turning clockwise) and the pump output is
set to less than 100%, the product may not
operate correctly.
▶
In this case, set the pump output to
5 = 100% using diagnostics code d.14.
▶
Remove the front casing. (→ Page 18)
4
5
6
7
A
1000
1300
6
Saturation 25 kPa
7
Saturation 17 kPa
A
Flow rate in circuit (l/h)
B
Available pressure
(kPa)
4
5
6
7
1000
1400
6
Saturation 25 kPa
7
Saturation 17 kPa
A
Flow rate in circuit (l/h)
B
Available pressure
(kPa)
A
33