Inverter
FR-E820-[]
FR-E840-[]
0008(0.1K)
—
0015(0.2K)
—
0030(0.4K)
0016(0.4K)
0050(0.75K)
0026(0.75K)
0080(1.5K)
0040(1.5K)
0110(2.2K)
0060(2.2K)
0175(3.7K)
0095(3.7K)
0240(5.5K)
0120(5.5K)
0330(7.5K)
0170(7.5K)
0470(11K)
0230(11K)
0600(15K)
0300(15K)
0760(18.5K)
0380(18.5K)
0900(22K)
0440(22K)
Inverter
FR-E820-[]
FR-E840-[]
0008(0.1K)
—
0015(0.2K)
—
0030(0.4K)
0016(0.4K)
0050(0.75K)
0026(0.75K)
0080(1.5K)
0040(1.5K)
0110(2.2K)
0060(2.2K)
0175(3.7K)
0095(3.7K)
0240(5.5K)
0120(5.5K)
0330(7.5K)
0170(7.5K)
0470(11K)
0230(11K)
0600(15K)
0300(15K)
0760(18.5K)
0380(18.5K)
0900(22K)
0440(22K)
*1
Pr.71 = "0, 3, 5, 6, 20, 23, 40, or 43" (standard motor)
*2
Pr.71 = "10, 13, 15, 16, 50, or 53" (constant-torque motor)
*3
Pr.71 = "70 or 73" (SF-PR)
*4
Pr.71 = "1800 or 1803" (GM-[])
NOTE
• When the Pr.0 and Pr.12 settings are changed from their initial values, the automatic change is not performed.
• When the SF-PR motor is selected (Pr.71 = "70 or 73"), the output current may become large due to a small load by setting
Pr.81 Number of motor poles according to the number of the SF-PR motor poles.
• When the SF-PR motor is used, the output current tends to increase compared with the case where the SF-JR or SF-HR motor
is used. Depending on the load conditions, the output current may increase even though the torque boost value has been
automatically changed. When the protective function such as the electronic thermal O/L relay (E.THT, E.THM) or stall
prevention (OL, E.OLT) is activated, adjust the Pr.0 Torque boost according to the load.
CAUTION
• Make sure to set this parameter correctly according to the motor used. Incorrect setting may cause the motor and the
inverter to overheat and burn.
Parameters referred to
Pr.0 Torque
boostpage 468
Pr.12 DC injection brake operation
Pr.14 Load pattern
selectionpage 472
Pr.96 Auto tuning
setting/statuspage 385
Pr.178 to Pr.189 (Input terminal function
384
15. (C) Motor Constant Parameters
15.1 Applied motor
Standard
*1
motor
FR-E820S-[]
ND
LD
0008(0.1K)
6
6
6
0015(0.2K)
6
6
6
0030(0.4K)
6
6
6
0050(0.75K)
6
4
6
0080(1.5K)
4
4
4
0110(2.2K)
4
4
4
—
4
3
4
—
3
3
2
—
3
2
2
—
2
2
2
—
2
2
2
—
2
2
2
—
2
2
2
Pr.12 value (%) after automatic change
Standard
*1
motor
FR-E820S-[]
ND
LD
0008(0.1K)
6
6
6
0015(0.2K)
6
4
6
0030(0.4K)
4
4
4
0050(0.75K)
4
4
4
0080(1.5K)
4
4
4
0110(2.2K)
4
4
4
—
4
4
4
—
4
4
2
—
4
2
2
—
2
2
2
—
2
2
2
—
2
2
2
—
2
2
2
voltagepage 476
selection)page 368
Pr.0 value (%) after automatic change
Constant-
torque
Pr.81 ≠ "2, 4,
Pr.81 =
*2
motor
6"
"2"
ND
LD
ND
LD
ND
6
4
4
4
6
4
4
4
6
4
4
4
4
4
3
7.4
4
3
2.5
5.8
4
2.5
2.5
6
2
2.5
2
6.4
2
2
2
4.5
2
2
1.5
4.4
2
1.5
1.5
3.5
2
1.5
1.5
4.5
2
1.5
1.5
4
2
1.5
1
2.5
Constant-
*3
torque
SF-PR
GM-[]
*2
motor
ND
LD
ND
LD
ND
6
4
4
6
4
4
4
6
4
4
4
4
4
4
2.5
4
4
2.5
2.5
4
4
2.5
2.5
4
2
2.5
2
2.5
2
2
2
2
2
2
1.5
2
2
1.5
1.5
1.5
2
1.5
1.5
1.5
2
1.5
1
(1.5) 1
2
1
1
1
*3
SF-PR
Pr.81 =
Pr.81 =
"4"
"6"
LD
ND
LD
ND
LD
4
4
4
4
4
6
4
4
4
4
4
6
7.4
4
6
4
6.4
6
5.8
6
5
6.4
3.7
4
6
5
4.5
3.7
3.3
5
6.4
4.5
4.5
3.3
4.2
4
4.5
4.5
3.7
4.2
3.3
4.5
4.4
3.7
4.5
3.3
3.8
3.7
3.5
4.5
3.3
3.8
3.5
4.5
4.5
3.3
3
3.5
3.5
3.3
4
3
3.2
3.5
3
3
2.5
3.2
3.4
3
3
(3.2) 3.4
3
3.4
2
3
2.5
3.4
*4
LD
6
4
4
4
4
2.5
2
2
1.5
1.5
(1.5)
1
*4
GM-[]
ND
LD
6
6
4
5
4
4.5
3.7
4.5
3.3
3
(3.2)
2