Replacement Parts; Disposal - Honeywell MHF49 Installation Instructions Manual

Magnetic heating filter
Table of Contents

Advertisement

Available languages

Available languages

Replacement parts

• Remove housing end cap [6].
• Clean magnetic filter.
• Screw the housing end cap [6] back on, applying a
torque of maximum 18 Nm ±10 %.
• Make certain that the O-ring [2] is correctly
positioned.
• Unscrew the air vent cap from the top of the filter
housing. Open only the inlet isolation valve until
water exits the air vent hole.
• Close the isolation valve.
• Screw the air vent cap back on water tight.
• Open both isolation valves.
7. Replacement parts
For the MHF49 there are no designated spare parts. In
normal operation no spare parts are needed.
In case of damage the whole MHF49 must be
replaced.

8. Disposal

Both the MHF49 and the associated packaging consist
mostly of recyclable raw materials.
• Dispose of packing and all recyclable materials
separately, properly and in an environmentally
friendly way.
9