CIRCULATION
HOSE
PUMP HOSE
THERMISTOR
LGE Internal Use Only
PUMP
BELLOWS
HEATER
1
Disassemble the cabinet cover.
2
Separate the pump hose, the bellows, the
circulation hose assembly from the pump
assembly.
3
Disassemble the pump assembly.
1
Disassemble the cabinet cover.
2
Separate 2 connectors from the heater.
3
Loosen the nut and pull out the heater.
CAUTION
• When assembling the heater, insert the
heater into the heater clip on the bottom of
the tub.
• Tighten the fastening nut so the heater is
secure.
1
Disassemble the cabinet cover.
2
Unplug the white connector from the
thermistor.
3
Pull it out by holding the bracket of the
thermistor.
38
Copyright © 2016 ~ 2017 LG Electronics Inc. All rights