Cutting or Extending the Pipe

Pipe cutter
Pipe
Pipe
Flare
Flare nut
Indoor outlet pipe
Connecting pipe
12
E-
1
Make sure that you have all the required tools (pipe cutter, reamer, flaring tool
and pipe holder).
2
If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut
edge remains at 90° with the side of the pipe (see below examples of correct
and incorrect cut edges).
Oblique
3
To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer.
CAUTION
Face the pipe down while removing the burrs to make sure
that burrs do not get in to the pipe.
4
Put a flare nut slightly into the pipe and modify the flare.
Outer Diameter (D)
ø6.35 mm
ø9.52 mm
ø12.70 mm
ø15.88 mm
ø19.05 mm
ø22.23 mm
5
Check if you flared the pipe correctly (see examples of incorrectly flared pipes
below).
Correct
Inclined
6
Align the pipes to connect them easily. Tighten the flare nuts first with your
hands, and then with a torque wrench, applying the following torque:
Outer Diameter
ø6.35 mm
ø9.52 mm
ø12.70 mm
ø15.88 mm
ø19.05 mm
ø22.23 mm
Note
Excessive torque can be cause of gas leakage.
In case brazing the pipe, the nitrogen gas must be blown into the pipe
(50 Pa). The joint must be accessible and serviceable.
CAUTION
Tighten the flare nut with torque wrench according to specified method.
If the flare nut is over-tightened, the flare may break and cause refrigerant
gas leakage.
Rough
Depth (A)
Thickness
0.8mm
1.3 mm
0.8mm
1.8 mm
0.8mm
2.0 mm
1.0mm
2.2 mm
1.0mm
2.2 mm
1.0mm
2.2 mm
Damaged
Cracked
Surface
Thickness
Torque (kgf•cm)
0.8mm
140~170
0.8mm
250~280
0.8mm
380~420
1.0mm
440~480
1.0mm
990~1210
1.0mm
990~1210
Burr