Code
Parameter
D.022
DHW demand
D.023
Heating mode status
D.024
Air pressure sensor actual
value
D.025
Ext. eBUS signal: Cylinder
charging
D.026
Auxiliary relay
D.027
Accessory relay 1
D.028
Accessory relay 2
D.029
Water circulation vol. ac-
tual value
D.033
Fan speed target value
D.034
Fan speed actual value
0020193966_04 ecoTEC exclusive Installation and maintenance instructions
Values
Unit
Min.
Max.
–
Current value
–
Current value
Current value
Pa
–
Current value
–
1
10
–
1
10
–
1
10
Current value
m³/h
Current value
rpm
Current value
rpm
Increment, select, explanation
Domestic hot water requirement via
C1/C2, impeller or APC
0: Off
1: On
Summer/winter mode (heating
off/on)
0: Blocked
1: Released
–
Domestic hot water generation
enabled by eBUS control
0: Off
1: On
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extraction hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not act-
ive)
9 = Anti-legionella pump (not act-
ive)
10 = Solar valve (not active)
Switching of relay 1 on the VR 40
"2 in 7" multi-functional module
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extraction hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not act-
ive)
9 = Anti-legionella pump (not act-
ive)
10 = Solar valve (not active)
Switching of relay 2 on the VR 40
"2 in 7" multi-functional module
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extraction hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not act-
ive)
9 = Anti-legionella pump (not act-
ive)
10 = Solar valve (not active)
Actual value: Circulation water
volume for flow sensor
–
–
Factory
Own
setting
setting
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
2
2
2
–
Not ad-
justable
–
Not ad-
justable
–
Not ad-
justable
47