Error Messages - Parker RE06M T Series Operation Manual

Proportional pressure valves with integrated electronics
Table of Contents

Advertisement

Operation Manual

Error messages

Malfunctions when using the ProPxD software program will be indicated via appropriate failure mes-
sages.
Failure messages and corrective actions:
Failure message
The Com Port is not available! Terminate the other program, or quit the message and select ano-
Unable to open COM port
There is no module/valve
connected or the communica-
tion is disturbed! Please check
also the interface!
Wrong password
Wrong input
Keep the entered para-me-
ters?
The chosen module/valve
isn´t the same as the connec-
ted hardware. Attention! Unsa-
ved parameters will be lost.
The chosen hardware isn´t
the same as the connected
module/valve.
Attention! Factory settings
will be changed! Transmit
anyhow?
file name.pxd already exists.
Do you want to replace the
file?
RE_-R_V obe_24-45-A-B 5715-651 UK 29.01.19
Proportional Pressure Valves
Series RE*T / R*V
Description/corrective action
ther RS232C port via the menu "Options > Port". Afterwards recon-
nect the parametrizing cable.
Com port is not available. Quit the message and select another
RS232C port via the menu "Options > Port". Afterwards reconnect
the parametrizing cable.
No data exchange possible. Either the electronic has been remo-
ved, the port is mismatched, or the connection will be disturbed by
strong electrical fields. Check if the Com port is set for "9600, 8, 1.
none, none" via the menu "Options > Port".
Retype the password, notice the exact spelling (case sensitivity).
An unvalid character or a value outside the permitted range has
been used at parameter entry.
During parameter loading from the electronics memory the preset
parameters from the left hand screen display may be rejected or
maintained.
In principle, parameters dedicated to a type which deviates from
the connected valve may be edited. However, for data transmitting
the correct valve has to be connected. If parameters will be loaded
from a valve which deviates from the selected one, the parameters
from the left hand side screen display of the program will be ove-
rwritten.
The wrong valve type has been selected from the database, afte-
rwards the function "send all" has been executed.
Default parameters has been read out from the database instead
from the valve via the function "receive all".
The file name already exists within the indicated directory. Select
another name, another directory or overwrite the existing file with
"OK".
20