MODEL #091-12PIM - AUTOMATIC BATTERY CHARGER
This charger is designed for vehicles with single batteries and either negative or positive ground.
INPUT: 120 Volts A.C., 50/60 Hz, 4 Amps
OUTPUT: 13.25 Volts D.C.
INTRODUCTION
This procedure defines the installation and wiring for the Auto
Charge 12 PIM Automatic Battery Charger. It is suggested that
the installer read the entire instruction manual to become
familiar with the tasks involved before starting.
The Auto Charge 12 PIM Battery Charger is a compact
completely automatic charger designed for installation on
vehicles with one (1) battery. The Auto Charge 12 provides
complete battery. Remote sensing permits long lines between
the charger and the batteries by compensating for the voltage
drop in the charging wires. An ammeter provides continuous
indication of the charger output.
Construction of the Auto Charge 12 PIM is extremely rugged
to withstand the shock and vibration normally encountered
by vehicle mounted equipment. The unit operates completely
automatically and stops charging the batteries when they
are fully charged. There is no trickle charge and therefore no
danger of overcharging and water boil-off. Any parasitic loads
on the battery such as radio, lights, etc., will be supplied by
current from the charger.
Any 120 volts loads when plugged into the GFI on the Auto-
Charge 12 PIM will be protected from ground faults. A separate
level operated circuit breaker protects the GFI connected
loads. This circuit breaker may also be used to disconnect
these loads from the line. The fuse on the Auto-Charge 12 PIM
protects the charger only.
INSTALLATION
The Auto Charge 12 PIM Automatic Battery Charger should be
Visit: www.evpeurope.com
Call: +44 (0) 1926 419441
E-mail: sales@evpeurope.com
EVP Ltd, Unit 4, Benford Court, Lower Cape, Warwick, CV34 5DA
TM
installed in an area with adequate ventilation. A power cord is
supplied for connection to 115 volts 60 Hz.
1.
Mount the charger using the four holes provided for this.
2. Connect the wiring from the battery to the Output
Terminal Strip. Spade lugs that have been securely
crimped, or soldered, should be used.
3. Double check all wiring before proceeding.
4. Wire the A.C. power line cord to 115VAC.
5. Pilot light will light to show that the charger has power.
6. The ammeter will indicate how much the batteries are
charging. A charging current limit of amperes is factory
set.
WARRANTY
All products of Kussmaul Electronics Company Inc. are
warranted to be free of defects of material or workmanship.
Liability is limited to repairing or replacing at our factory,
without charge, any material or defects which become
apparent in normal use within 3 years from the date the
equipment was shipped. Equipment is to be returned, shipping
charges prepaid and will be returned, after repair, shipping
charges paid.
Kussmaul Electronics Company, Inc. shall have no liability for
damages of any kind to associated equipment arising from the
installation and /or use of the Kussmaul Electronics Company,
Inc. products. The purchaser, by the acceptance of the
equipment, assumes all liability for any damages which may
result from its installation, use or misuse, by the purchaser, his
or its employees or others.
Company Registration Number: 9121263
VAT number: 196484653

Advertisement

loading

Summary of Contents for KUSSMAUL EVP AUTO CHARGE 12 PIM

  • Page 1 GFI connected loads. This circuit breaker may also be used to disconnect Kussmaul Electronics Company, Inc. shall have no liability for these loads from the line. The fuse on the Auto-Charge 12 PIM damages of any kind to associated equipment arising from the protects the charger only.
  • Page 2 INSTALLATION WIRING DIAGRAM AUTO CHARGE 12 PIM, 091-11PIM INSTALLA TION GUIDE & MANUAL FIGURE 1: Installation Wiring Diagram POWER AUTO CHARGE 12 PIM SENSE BATTERY NOTE: The sense leads MUST be connected for the charger to operate. IMPORTANT: Battery + and - wire size is 12 awg. Sense + and - wire size is 16 awg. Wire size is for a maximum length of 20 feet.
  • Page 3 SPECIFICATION & OUTLINE AUTO CHARGE 12 PIM, 091-11PIM INSTALLA TION GUIDE & MANUAL SPECIFICATIONS: Input: 120 Volts A.C., 60Hz, 4 Amps Output: Adjustable 13.3 Volts Nominal Output Current: 0-12 Amps D.C., Current Limit Charge Indicator: 0-15 Amps 5% SPECIFICATIONS Weight: 16 lbs Input: 120 Volts A.C., 60Hz, 4 Amps Output: Adjustable 13.3 Volts nominal Outpu Current: 0-12 Amps D.C., current limit...

This manual is also suitable for:

Evp 091-12pim