Bradford White EVERHOT IGI-180C Series Installation And Operating Instruction Manual page 47

Tankless gas water heater for interior installation
Hide thumbs Also See for EVERHOT IGI-180C Series:
Table of Contents

Advertisement

FIRST AID FOR SCALDS
1. Remove all wet clothing quickly. Wet clothing retains the heat.
2. Apply cold water to burned area for 30 minutes to reduce the heat in the skin and prevent deeper
burning. Never use butter, oils, or ointment to cover the burn. They may retain the heat.
3. Use a blanket to keep the scalded person warm.
4. Seek medical advice.
ERROR MESSAGES ON REMOTE TEMPERATURE CONTROL DISPLAY
The Bradford White EVERHOT® continuous flow water heaters have the ability to monitor and display
any operating faults on the control display. The error messages will display on the monitor and will assist
in servicing the water heater. The following is a listing of the error codes, which may flash on the monitor
in case of a malfunction with the water heater. Please quote the code displayed when calling for service.
Code
Displayed
10
Air supply or exhaust blockage
11
12
Flame Failure, grounding failure
14
16
32
Outlet water temperature faulty
33
Heat exchanger outlet water temperature faulty
34
52
Modulating Solenoid Valve signal abnormal
61
71
Solenoid Valve Driving Circuit Faulty
72
LC
Scale build-up in Heat Exchanger
(00)
(When checking maintenance code history, "00" is
If any of the above error codes are seen flashing on the remote display, call for service.
Failure to remedy faults may result in severe burns, scalds, and/or death.
Fault
No Ignition
Thermal Fuse
Over Temperature Warning
Combustion air sensor faulty
Combustion Fan Failure
Flame Sensing Device Faulty
substituted for "LC").
Check for a restriction in the exhaust
Check to make sure the gas supply is
Make sure gas is turned on at the
water heater; check for obstructions in
Excessive temperatures, wrong dip
switch setting, incorrect manifold
Outlet sensor or wiring may be
H.E. outlet sensor or wiring may be
Check gas control and wiring
Combustion fan or wiring faulty
Check all gas solenoids and wiring
Lack of flame sense – check flame rod
exchanger – needs to be flushed.
WARNING
47
Remedy
vent.
on to the water heater.
exhaust vent.
Heat exchanger overheated
pressure or gas type.
defective
defective.
Thermistor or wiring faulty
and wiring connections.
Build up of lime scale in heat

Advertisement

Table of Contents
loading

This manual is also suitable for:

Everhot igi-180r series

Table of Contents