Remote Main Control Installation:
Follow the same control installation procedure as outlined under "Temperature Control Installation" for
residential models. The only exception is that only one remote temperature control can be installed.
Do not attempt to connect the remote controls with the power on to the water heater. There are 120 volt
terminals and wiring next to the remote control connections inside the unit. All servicing and wiring must
be performed by a qualified installer.
INITIAL OPERATION AND TESTING OF CONTROLS (INSTALLER ONLY)
1. Turn on power to the water heater and fully open a hot water tap.
2. Check the operation of the water heater.
control(s). Check the operation of the power failure protection system (drain solenoids).
3. Explain the proper operation of the new Bradford White EVERHOT® water heater to the
customer.
Main Control for Commercial Models (Fig. 7)
Fig. 8 Control Wiring Connections Inside Water Heater
WARNING
Check the operation of the remote temperature