TROUBLESHOOTING
EB-42 Error code [E-bb] (Abnormality I constant adjustment volume
system)
Before carrying out troubleshooting, connect terminal box [SCS] and [69], and open all of [EXIT], [AIS],
[AIG], [74A], [74], and [SRG].
Turn starting switch OFF.
Disconnect CN3-1.
Turn starting switch OFF.
Disconnect CN3-1 and CN3-2.
Turn starting switch OFF.
Disconnect all connectors.
Table 1
CN3-2 (female), CN3-1 (female)
Between CN3-2 (6) and CN3-1 (14)
12-362
Is resistance between CN3-1
(female) (6) and (14) 1k1.35
k
?
Ω
YES
Is resistance between CN3-2
(female) (6) and CN3-1 (female)
(14) as shown in Table 1?
YES
Is resistance between CN3-2
(female) (6) and surrounding wiring
harnesses more than 100 k
?
Ω
(Except portions of related circuit
YES
Volume
Resistance value
Fully closed (full left)
Max. 1.1 k
Fully open (full right)
1.8 2.0 k
Cause
NO
Defective panel
NO
Defective panel
!
NO
Defective panel
Defective engine controller
Ω
Ω
EB-42
Remedy
Remedy
Remedy
Remedy
Remedy
170-3 SERIES