Removing The Heating Element; Descaling The Heating Element - Bosch Tronic 3000T ES2.5 Installation Manual And Operating Instructions

Table of Contents

Advertisement

Available languages

Available languages

element). Upon inspection, the anode rod surface should
appear smooth. If the rod surface appears pitted, bumpy, rusty,
or if the rod is missing completely, then it must be replaced.
To access the anode rod:
▶ Remove the heating element (see Section 5.4 Removing
the heating element).
Original anode rod sizes
ES2.5, ES4: length 6½", diameter 5/8"
ES8:length 8¼", diameter 5/8"
Certain installations may require more frequent replacement of
the anode rod:
recirculation applications;
poor water quality;
galvanic/electrolytic corrosion
high flow applications
In the event of poor water quality, Bosch recommends
consulting a local water treatment professional for water
treatment options. Always ensure the water heater is grounded.
Models ES2.5 and ES4 must be connected only to a properly
grounded outlet. Damage resulting from poor water quality or
failure to replace the anode rod is not covered under the
manufacturer's warranty. For additional questions, please call
Bosch Technical Service.
5.4

Removing the heating element

▶ Turn off power supply and drain the heater (see previous
section).
▶ Remove the front cover plate, disconnect terminals X, Y and
T.
▶ Unscrew the 4 heating element retaining nuts F.
▶ Remove thermostat temperature sensor from well [B]
located on the element assembly.
▶ Remove the element G.
B
G
Z
F
X
Y
T
Fig. 9
Tronic 3000T – 6 720 892 061 2019/02
Fig. 10
5.5
Scale deposits can affect the heating capability of the element.
Heavy scale can even cause damage to the element. The
element can be descaled either chemically or manually:
▶ Soak the element in white vinegar or other descaling
solution.
▶ Once descaled, rinse well with fresh water, to which you
should add some baking soda,
-or-
▶ Once the element has dried, use a soft brush (non metallic
to prevent damaging the stainless steel sheath) on
element.
▶ Brush the dried mineral off.
H
E
A
6720801072-09.1V
G

Descaling the heating element

Maintenance
6720801072-10.1V
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tronic 3000t es4Tronic 3000t es8Tronic 3000t es2.5 caTronic 3000t es4 caTronic 3000t es8 ca

Table of Contents