Troubleshooting - ZyXEL Communications BPS-120 User Manual

Stand-alone backup power system
Hide thumbs Also See for BPS-120:
Table of Contents

Advertisement

Table 4 BPS-120 Front Panel DC Output LEDs State Definitions
PORT LED
COLOR
INDICATIONS
DEVICE
Amber
FAULT
DEVICE
Red
FAULT

3 Troubleshooting

Make sure that the BPS-120 is plugged into an appropriate AC power supply.
Table 5 BPS-120 Troubleshooting Tips
PROBLEM
The STANBY
LED is off.
The STANDBY
LED is on.
The FAULT LED
is red.
BPS-120 User's Guide
DC
OUTPUT
LED
STATUS
Off
The BPS-120 has detected an external or
internal fault. See Table 5.
On
The BPS-120 has detected an external or
internal fault. See Table 5.
CONDITION
Faulty or not connected AC
power supply.
The BPS-120 is in standby
mode.
The BPS-120 has an internal
hardware system fault (PWR,
TEMP, or FAN LEDs are
red).
18
DESCRIPTION
CORRECTIVE ACTION
Make sure you are using the
correct power line cord and it is
plugged into an appropriate
100/240 VAC power supply
receptacle. Check the power line
fuse.
Unplug the power line cord and
plug it in again. Turn the BPS-
120 on using the rear panel
switch. If the error persists you
should contact your vendor or
Zyxel for servicing.
Press the STANDBY/ACTIVE
button to put the BPS-120 into
active mode.
Monitor the PWR, TEMP, and
FAN LEDs, then turn the BPS-
120 off or disconnect external
devices.

Advertisement

Table of Contents
loading

Table of Contents