Using the QAA73 temperature regulator, it is possible to enter into main board LMU34 parameters.
En utilisant la commande
lectronique LMU 34.
The editable parameters are those between 504 and 652 (parameters 650 and 652 are only reading
parameters).
Proceed as follows to access this parameters:
1) Simultaneously press keys 1-4 on QAA73 remote control for about 3 seconds. The "Initialising
BMU parameters" appears on the display (line 725).
2) Simultaneously press keys 1-2 on QAA73 temperature regulator for about 3 seconds. The
"Initialising BMU SERVICE" (line 504 "TkSmax").
3) Press keys 1-2 to scroll through the list of parameters.
4) To change the value of the selected parameter, press key 3-4 to decrease or increase the value
respectively.
5) Press key 5 to enter the new values and exit programming of the boiler's electronic main board.
Les param tres qui peuvent tre modifi s sont compris entre 504 et 652 (Les param tres 650 et 652 sont
seulement de lecture).
La proc dure pour acc der
1) appuyer en m me temps sur les boutons 1-4 pour environ 3 seconds, jusqu'
display de l' crit "Initialisation param trage BMU" (par. 725);
2) appuyer en m me temps sur les boutons 1-2 pour environ 3 seconds, jusqu'
display de l' crit "Initialisation chauffagiste BMU" (par. 504 "TkSmax");
3) appuyer sur les boutons 1-2 pour s lectionner les param tres;
4) Pour modifier les param tres affich s appuyer les boutons 3-4 pour diminuer ou augmenter la
valeur;
5) appuyer sur le bouton 5 pour m moriser et sortir du niveau de programmation.
A
DVANCED
distance QAA73 il est possible changer quelque param tres de la carte
ces param tres est la suivante:
P
ARAMETERS
l'affichage sur le
l'affichage sur le

Advertisement

loading

This manual is also suitable for:

Luna ht 380Luna ht 1.330Luna ht 1.450Luna ht 330