1.1

general instructions

WARNING
!
Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door opened
or removed.
Provide adequate clearance for servicing and operating the appliance.
Provide adequate ventilation.
Never obstruct the front opening of the appliance.
Objects placed in front of the appliance must be kept a minimum of 48" (121.9cm) from the front face of
the appliance.
Surfaces around and especially above the appliance can become hot. Avoid contact when appliance is
operating.
Fire risk. Explosion hazard.
High pressure will damage valve. Disconnect gas supply piping before pressure testing gas line at test
pressures above 1/2 PSIG. Close the manual shut-off valve before pressure testing gas line at test
pressures equal to or less than 1/2 PSIG (35mb).
Use only Wolf Steel approved optional accessories and replacement parts with this appliance using non-
listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could result
in a safety hazard and will void the warranty and certifi cation.
Do not use a blower insert, heat exchanger insert or any other accessory not approved for use with this
appliance.
Thoroughly clean the chimney, fl ue and existing appliance
before installing the new appliance into it. Do not burn solid
fuels in any appliance that is equipped with this gas log set.
The installation of this appliance must conform with local
codes or in the absence of local codes, it must conform to
ANSI Z.223.1 or the CAN/CGA B149.
Do not operate appliance in the presence of gasoline or
other fl ammable liquids and vapours. Keep area clear of
other combustible materials. The appliance and its shut off
must be disconnected from the gas supply piping system
before any pressure testing of the system is done.
Installation practices vary from region to region and it is important to know the specifi cs that apply to your area,
For example: in Massachusetts State:
This product must be installed by a licensed plumber or gas fi tter when installed within the
commonwealth of Massachusetts.
The appliance damper must be removed or welded in the open position prior to installation of a
appliance insert or gas log.
The appliance off valve must be a "T" handle gas cock.
The fl exible connector must not be longer than 36 inches.
The appliance is not approved for installation in a bedroom or bathroom unless the appliance is a direct
vent sealed combustion product.
A carbon monoxide detector is required in all rooms containing gas fi red appliances.
No external electricity (110 volts or 24 volts) is required for the gas system operation.

1.0 general information

general information
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
www.nficertified.org