5.7.2.
Checking Data that are Sent and Received
Confirm that the correct data are sent and received.
1
To check the data, go to the
Controller Tags menu and select the
Monitor Tags tab.
2
Expand out Tag names by clicking the + symbol next to each tag name. In the first byte of the
created Input Tag (V680S: I Data), there is a value of 1. This means that the RFID System is
READY.
For detailed information on I/O Space, see RFID System V680S Series User's Manual,
Section 5. Host Communications Specifications.
3
To test the output of the RFID
System, send a read command to
the device. Set the CmdCode to 1
(V680S: O.Data[2]) then enter "1" in
the first bit of the Output tag V680S:
O.Data[0] to execute the command.
18