Instructions for the Installer

Technical Data
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY:
APPLIANCE GAS SUPPLY:
Dimensions
Height
Depth
Width
Oven Capacity
Hob
Rear left burner (semi-rapid)
Front left burner (ultra-rapid triple crown)
Rear right burner (semi-rapid)
Front right burner (auxiliary)
TYPE OF
CHARACTERISTICS
GAS
VALUE =
NATURAL
GAS
Hs 37.78 MJ/m
3
20 mbar
Ws 50.72 MJ/ m
3
LPG GAS
VALUE =
28-30/37
Hs 49.92 MJ/Kg
mbar
Ws 82.09 MJ/ m
3

Important Safety Requirements

This appliance must be installed in accordance with the
Gas Safety (Installation and Use) Regulations (current
addition) and the I.E.E. Wiring Regulations.
Detailed recommendations are contained in the following
British Standard Codes of Practice - B.S. 6172, B.S.
5440: Part 2 and B.S. 6891: Current Editions.
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S. 813 Current
Editions and the ETCI Rules for Electrical Installations.
Provision for Ventilation
The room containing the cooker should have an air
supply in accordance with B.S. 5440: Part 2: Current
Editions.
The following requirements for ventilation must be met.
30
II2H3+
Natural Gas 20 mbar
900 mm
600 mm
600 mm
56 litres / 1.97 Cu. ft
2,0 kW
4,0 kW
2,0 kW
1,0 kW
BURNER
POSITION
MAX
NOMINAL THERMAL
POWER kW
4.0
NOMINAL FLOW
RATE m
/h
0.381
3
NOZZLE REFERENCE
146
1/100 mm
NOMINAL THERMAL
POWER kW
4.0
NOMINAL FLOW
RATE g/h
288
NOZZLE REFERENCE
1/100 mm
Oven
Top heating element
Bottom heating element
Oven element
Grill Element (inner)
Grill Element (full)
Pizza Oven
Convection heating element
Pyrolytic cleaning function
Convection fan
Oven light
Total rating
Supply voltage (50 Hz)
ULTRA RAPID
SEMI-RAPID
(large)
(medium)
MIN
MAX
1.20
2.0
0.114
0.190
Adjust.
96
1.20
2.0
86
144
98
56
71
The cooker should not be installed in a bed sitting room
with a volume of less than 20m
of volume less 5m
is required; if it is installed in a room of volume between
5m
and 10m
3
required, while if the volume exceeds 11m
required. However, if the room has a door which opens
directly to the outside, no air vent is required even when
the volume is between 5m
If there are other fuel burning appliances in the same
room, B.S. 5440: Part. 2: Current Editions should be
consulted to determine the requisite air vent
requirements.
For appliances installed in the Republic of Ireland please
refer to the NSAI- Domestic Gas Installation I.S. 813
Current Editions Table Four.
AUXILIARY
(small)
MIN
MAX
0.45
1.0
0.043
0.095
Adjust.
70
0.45
1.0
32
72
32
50
, if it is installed in a room
3
3
an air vent of effective area of 110cm
, an air vent of effective area 50cm
3
3
and 11m
3
.
800 W
1,000 W
1,800 W
1,650 W
2,450 W
3,000 W
2,000 W
2,450 W
30 W
40 W
3,100 W
230 V
MIN
0.33
0.031
Adjust.
0.33
24
28
2
is
2
no air vent is
3