DG-8 specifications
COMPONENT
No. of Independent Pressure Channels
Digital Communication
Accuracy
1,2
Display Resolution
Pressure Range
Units of Measure
Display
Power
Battery Life
Auto-off
Dimensions
Weight
Recommended Calibration Interval
Operating Temperature Range
Storage Temperature Range
Typical Conditions are a temperature range of 54° to 90° F, and a two year calibration interval.
1
As Calibrated Accuracy is +/- (0.4% of reading + 0.045 Pa) under controlled conditions of 67° to 77° F, four
2
month calibration interval, and pressure readings averaged for five seconds. All gauges are verified to meet
this specification at all calibration pressures.
For use at temperature conditions outside the typical conditions in Note 1, or the as-calibrated range in
3
Note 2, add an additional 0.037% of pressure reading per degree F over the stated range.
Storage limits are based on batteries. Storing outside these limits may require battery replacement.
4
Specifications subject to change without notice.
Minneapolis Blower Door
and TECTITE
trademarks of The Energy Conservatory.

SPECIFICATIONS

One
Bluetooth Low Energy, USB 2.0
0.9% of pressure reading or 0.00048 in. H
whichever is greater
0.001 in. H
0.1 Pa for readings up to 999.9 Pa
1 Pa for readings over 1000 Pa
-10 to +10 in. H
Pa and in. H
320 x 240 pixels, 2-inch diagonal, backlit color TFT LCD
Lithium-Ion Polymer Rechargeable Battery 2,000 mAh
with USB-C
Typically over 22 hours of continous use
30 minutes
4.84 x 2.39 x 1.02 inches (123 x 61 x 26 mm)
6.4 oz (182 g)
24 months
32° F to 115° F (0° C to 45° C)
3
Less than one month: 15° F to 115° F (-10° C to 45° C)
4
One month up to one year: 32° F to 77° F (0° C to 25° C)
are trademarks of The Energy Conservatory. Duct Blaster
O
2
O (-2,500 to +2 ,500 Pa)
2
O
2
charger/power adapter included
®
5
O (0.12 Pa),
2
and TrueFlow
are registered
®
®