TABLE 6: COOLING CAPACITY DH090 (7-1/2 TON) UNIT
Air On
Temperature of Air on Condenser Coil 75°F
Evap. Coil
Tot.
Tot.
WB
1
CFM
Cap.
Input
(°F)
(MBH)
(kW)
72
102.7
5.7
67
98.7
5.6
2250
62
95.0
5.6
57
96.7
5.5
72
105.1
5.7
67
101.0
5.6
2625
62
97.2
5.6
57
98.9
5.5
72
107.5
5.7
67
103.3
5.6
3000
62
99.4
5.6
57
101.2
5.5
72
108.5
5.7
67
104.3
5.6
3375
62
100.4
5.6
57
102.2
5.5
72
109.6
5.7
67
105.4
5.6
3750
62
101.4
5.6
57
103.3
5.5
Temperature of Air on Condenser Coil 95°F
72
94.3
6.7
67
87.3
6.7
2250
62
82.4
6.5
57
80.1
6.5
72
96.6
6.8
67
89.4
6.7
2625
62
84.4
6.6
57
82.1
6.6
72
98.9
6.8
67
91.5
6.7
3000
62
86.4
6.6
57
84.0
6.6
72
100.6
6.9
67
93.1
6.8
3375
62
87.9
6.7
57
85.5
6.6
72
102.4
6.9
67
94.7
6.8
3750
62
89.4
6.7
57
87.0
6.7
Temperature of Air on Condenser Coil 115°F
72
80.6
7.9
67
72.0
7.7
2250
62
69.6
7.6
57
67.8
7.6
72
82.9
7.9
67
74.1
7.7
2625
62
71.6
7.7
57
69.7
7.7
72
85.2
8.0
67
76.1
7.8
3000
62
73.6
7.7
57
71.6
7.7
72
86.2
8.0
67
77.1
7.8
3375
62
74.5
7.7
57
72.5
7.8
72
87.3
8.1
67
78.0
7.9
3750
62
75.4
7.8
57
73.4
7.8
1 These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2 These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
14
Sensible Capacity (MBH)
2
Return Dry Bulb (°F)
86
83
80
77
60.1
53.7
47.3
40.9 34.5
75.6
69.2
62.8
56.4 50.0 43.5 37.1
95.0
87.3
80.9
74.5 68.0 61.6 55.2
96.7
90.6
84.1
77.7 71.3 64.9 58.5
65.5
57.9
50.3
42.8 35.2
82.0
74.4
66.8
59.2 51.6 44.0 36.5
97.2
93.4
86.1
78.5 70.9 63.3 55.7
98.9
95.9
89.6
82.0 74.4 66.8 59.2
70.9
62.1
53.4
44.6 35.9
88.3
79.5
70.8
62.0 53.3 44.5 35.8
99.4
99.4
91.2
82.5 73.8 65.0 56.3
101.2
101.2
95.0
86.2 77.5 68.7 60.0
75.3
65.4
55.4
45.4 35.5
94.8
83.4
73.5
63.5 53.6 43.6 33.6
100.4
100.4
95.9
85.9 76.0 66.0 56.0
102.2
102.2
99.1
89.2 79.2 69.2 59.3
79.8
68.6
57.4
46.2 35.1
101.3
87.3
76.2
65.0 53.8 42.6 31.5
101.4
101.4
100.5 89.4 78.2 67.0 55.8
103.3
103.3
103.3 92.1 80.9 69.7 58.6
56.3
49.8
43.4
37.0 30.6
71.1
64.7
58.3
51.9 45.5 39.1 32.7
82.4
77.6
71.2
64.8 58.4 51.9 45.5
80.1
78.0
71.6
65.2 58.8 52.4 46.0
62.1
54.5
46.9
39.4 31.8
78.2
70.6
63.0
55.4 47.9 40.3 32.7
84.4
82.0
76.9
69.4 61.8 54.2 46.6
82.1
81.0
77.4
69.8 62.2 54.7 47.1
67.9
59.2
50.5
41.7 33.0
85.2
76.5
67.7
59.0 50.2 41.5 32.8
86.4
86.4
82.7
73.9 65.2 56.4 47.7
84.0
84.0
83.2
74.4 65.7 57.0 48.2
73.1
63.2
53.2
43.2 33.3
90.0
81.4
71.4
61.5 51.5 41.5 31.6
87.9
87.9
86.1
76.1 66.1 56.2 46.2
85.5
85.5
85.1
75.1 65.2 55.2 45.2
78.3
67.1
55.9
44.8 33.6
94.7
86.3
75.1
63.9 52.8 41.6 30.4
89.4
89.4
89.4
78.2 67.1 55.9 44.7
87.0
87.0
87.0
75.8 64.6 53.4 42.2
51.1
44.6
38.2
31.8 25.4
64.6
58.1
51.7
45.3 38.9 32.5 26.1
69.6
65.8
59.4
52.9 46.5 40.1 33.7
67.8
66.0
59.5
53.1 46.7 40.3 33.9
57.1
49.5
41.9
34.3 26.7
70.3
64.3
56.7
49.1 41.5 34.0 26.4
71.6
69.7
65.1
57.5 49.9 42.3 34.7
69.7
68.8
65.3
57.7 50.1 42.5 34.9
63.1
54.3
45.6
36.8 28.1
76.1
70.4
61.7
52.9 44.2 35.4 26.7
73.6
73.6
70.8
62.0 53.3 44.5 35.8
71.6
71.6
71.0
62.2 53.5 44.7 36.0
68.4
58.5
48.5
38.5 28.6
77.1
74.2
65.6
55.7 45.7 35.7 25.8
74.5
74.5
73.1
63.1 53.2 43.2 33.2
72.5
72.5
72.2
62.2 52.3 42.3 32.3
73.8
62.6
51.4
40.2 29.1
78.0
78.0
69.6
58.4 47.2 36.1 24.9
75.4
75.4
75.4
64.2 53.0 41.9 30.7
73.4
73.4
73.4
62.2 51.0 39.9 28.7
Temperature of Air on Condenser Coil 85°F
*
Tot.
Tot.
1
Cap.
Input
(MBH)
(kW)
74
71
68
-
-
98.5
6.2
93.0
6.1
88.7
6.1
88.4
6.0
-
-
100.9
6.2
95.2
6.1
90.8
6.1
90.5
6.1
-
-
103.2
6.3
97.4
6.2
92.9
6.1
92.6
6.1
-
-
104.6
6.3
98.7
6.2
94.2
6.1
93.9
6.1
-
-
106.0
6.3
100.1
6.2
95.4
6.1
95.1
6.1
Temperature of Air on Condenser Coil 105°F
-
-
87.5
7.3
79.7
7.2
76.0
7.1
74.0
7.1
-
-
89.8
7.4
81.8
7.2
78.0
7.1
75.9
7.1
-
-
92.1
7.4
83.8
7.3
80.0
7.2
77.8
7.2
-
-
93.4
7.4
85.1
7.3
81.2
7.2
79.0
7.2
-
-
94.8
7.5
86.4
7.3
82.4
7.2
80.2
7.2
Temperature of Air on Condenser Coil 125°F
-
-
73.7
8.4
64.4
8.2
63.2
8.1
61.6
8.2
-
-
76.0
8.5
66.4
8.2
65.2
8.2
63.5
8.2
-
-
78.3
8.5
68.4
8.3
67.2
8.2
65.4
8.3
-
-
79.0
8.6
69.0
8.4
67.8
8.3
66.0
8.3
-
-
79.7
8.7
69.7
8.4
68.4
8.3
66.6
8.4
246646-YTG-C-0606
Sensible Capacity (MBH)
2
Return Dry Bulb (°F)
86
83
80
77
74
58.2 51.8 45.4 39.0 32.5
73.4 67.0 60.5 54.1 47.7 41.3 34.9
88.7 82.4 76.0 69.6 63.2 56.8 50.4
88.4 84.3 77.9 71.5 65.0 58.6 52.2
63.8 56.2 48.6 41.1 33.5
80.1 72.5 64.9 57.3 49.7 42.2 34.6
90.8 87.7 81.5 73.9 66.3 58.8 51.2
90.5 88.5 83.5 75.9 68.3 60.7 53.2
69.4 60.7 51.9 43.2 34.4
86.8 78.0 69.3 60.5 51.8 43.0 34.3
92.9 92.9 87.0 78.2 69.5 60.7 52.0
92.6 92.6 89.1 80.3 71.6 62.8 54.1
74.2 64.3 54.3 44.3 34.4
92.4 82.4 72.5 62.5 52.5 42.6 32.6
94.2 94.2 91.0 81.0 71.0 61.1 51.1
93.9 93.9 92.1 82.1 72.2 62.2 52.3
79.0 67.9 56.7 45.5 34.3
98.0 86.8 75.6 64.5 53.3 42.1 30.9
95.4 95.4 95.0 83.8 72.6 61.4 50.3
95.1 95.1 95.1 83.9 72.8 61.6 50.4
53.7 47.2 40.8 34.4 28.0
67.8 61.4 55.0 48.6 42.2 35.8 29.4
76.0 71.7 65.3 58.9 52.4 46.0 39.6
74.0 72.0 65.6 59.2 52.7 46.3 39.9
59.6 52.0 44.4 36.8 29.3
74.3 67.4 59.9 52.3 44.7 37.1 29.5
78.0 75.8 71.0 63.4 55.8 48.3 40.7
75.9 74.9 71.3 63.8 56.2 48.6 41.0
65.5 56.8 48.0 39.3 30.5
80.7 73.5 64.7 56.0 47.2 38.5 29.7
80.0 80.0 76.7 68.0 59.2 50.5 41.7
77.8 77.8 77.1 68.3 59.6 50.8 42.1
70.8 60.8 50.8 40.9 30.9
83.5 77.8 68.5 58.6 48.6 38.6 28.7
81.2 81.2 79.6 69.6 59.6 49.7 39.7
79.0 79.0 78.6 68.7 58.7 48.7 38.8
76.0 64.9 53.7 42.5 31.3
86.4 82.2 72.4 61.2 50.0 38.8 27.6
82.4 82.4 82.4 71.2 60.0 48.9 37.7
80.2 80.2 80.2 69.0 57.8 46.6 35.5
48.4 42.0 35.6 29.2 22.8
61.3 54.8 48.4 42.0 35.6 29.2 22.8
63.2 59.9 53.5 47.0 40.6 34.2 27.8
61.6 59.9 53.5 47.1 40.7 34.3 27.8
54.5 47.0 39.4 31.8 24.2
66.4 61.1 53.5 46.0 38.4 30.8 23.2
65.2 63.5 59.1 51.6 44.0 36.4 28.8
63.5 62.7 59.2 51.6 44.0 36.4 28.9
60.6 51.9 43.1 34.4 25.6
68.4 67.4 58.6 49.9 41.1 32.4 23.6
67.2 67.2 64.8 56.1 47.3 38.6 29.8
65.4 65.4 64.9 56.1 47.4 38.6 29.9
66.1 56.1 46.1 36.2 26.2
69.0 69.0 62.7 52.8 42.8 32.8 22.9
67.8 67.8 66.6 56.6 46.7 36.7 26.8
66.0 66.0 65.8 55.8 45.8 35.9 25.9
71.5 60.3 49.2 38.0 26.8
69.7 69.7 66.8 55.6 44.5 33.3 22.1
68.4 68.4 68.4 57.2 46.0 34.8 23.7
66.6 66.6 66.6 55.4 44.3 33.1 21.9
Unitary Products Group
*
71
68
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-