Cooling Capacity - With Variable Speed Furnaces - York H*RE024 Technical Manual

Split-system air conditioners 14 seer 2 thru 5 nominal tons
Table of Contents

Advertisement

COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued)
FURNACE**
UNIT MODEL
CFM RANGE
(MIN.-MAX.)
1650
H2RE060S06
2150
TXV = Use 1TV700 Series Kit.
1.
*
Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
**
Refer to Quick Selection Chart for specific furnace match-up.

COOLING CAPACITY - With Variable Speed Furnaces

VARIABLE SPEED
UNIT MODEL
FURNACE MODEL
P1DUA12V
P1DUA12V
P1DUA12V
P1XDB12V
H1RE024S06
P1XUB12V
P1XUB12V
P1XUB12V
P1XUB12V
P1DUA12V
P1DUA12V
H1RE030S06
P1DUB16V
P1XDB12V
P1XUB12V
P1DUB16V
P1DUC20V
P1DUC20V
P1DUC20V
H1RE036S06
P1DUC20V
P1XDB12V
P1XDD20V
P1XUB12V
P1DUC20V
P1DUC20V
P1DUC20V
P1DUC20V
H2RE042S06
P1DUC20V
P1DUC20V
P1DUC20V
P1XDD20V
P1XDD20V
P1DUC20V
P1DUC20V
H2RE048S06
P1DUC20V
P1XDD20V
P1XDD20V
P1DUC20V
P1DUC20V
P1XUC20V
H2RE060S06
P1XUC20V
P1XUD20V
P1XUD20V
P1XUD20V
P1XUD20V
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
TXV = Use 1TV700 Series Kit.
2.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
Unitary Products Group
COIL
W
MODEL
21,24
G1FA060S21,24
24
G2FD060S24
24
G2FD061H24
-
G1HD060
24
G1NA060S24T
21,24
G1UA060S21,24
1
W
COIL MODEL
1 PH 14 SEER AC / P1DU / P1XD / P1XU - VARIABLE SPEED
G1FA036S14
14
G1UA036S14
14
G2FD035S14
14
G2FD030S17
17
G1FA036S17
17
G1UA036S17
17
G2FD030S17
17
G2FD036S17
17
G1FA036S14
14
G1UA036S14
14
G2FD036S17
17
G2FD036S17
17
G2FD036S17
17
G2FD036S17
17
G1FA048S21
21
G1UA048S21
21
G2FD036S21
21
G2FD048S21
21
G2FD036S17
17
G2FD048S24
24
G2FD036S17
17
G1FA048S21
21
G1FA060S21
21
G1UA048S21
21
G1UA060S21
21
G2FD042S21
21
G2FD048S21
21
G2FD048S21
21
G2FD048S24
24
G2FD060S24
24
G1FA060S21
21
G1UA060S21
21
G2FD048S21
21
G2FD060S24
24
G2FD060S24
24
G1FA060S21
21
G1UA060S21
21
G1FA060S21
21
G1UA060S21
21
G1FA060S24
24
G1UA060S24
24
G2FD060S24
24
G2FD061H24
24
NET MBH
RATED
CFM
TOTAL
SENS.
1900
53.5
37.1
1900
53.5
37.1
2050
54.5
39.1
1900
52.5
36.0
1900
53.0
35.9
1900
53.5
37.1
NET MBH
RATED
CFM
TOTAL
SENS.
870
25.4
18.0
870
25.4
18.0
870
25.2
17.9
830
26.0
17.9
870
25.4
18.0
870
25.4
18.0
870
25.4
17.9
870
25.8
18.1
1000
28.8
20.0
1000
28.8
20.0
1000
30.0
20.7
1040
30.2
20.7
1020
29.2
20.7
1200
34.4
24.5
1200
36.2
25.3
1200
36.2
25.3
1200
34.6
24.8
1200
36.0
25.7
1130
34.8
24.5
1195
36.2
25.7
1200
34.4
24.5
1400
39.5
28.4
1400
41.0
29.6
1400
39.5
28.4
1400
41.0
29.6
1400
39.5
28.2
1420
40.0
28.9
1420
40.0
28.9
1365
41.0
28.9
1420
41.5
33.8
1605
46.5
33.9
1605
46.5
33.9
1605
45.5
33.2
1580
47.0
33.9
1580
52.5
34.3
1630
53.0
34.9
1630
53.0
34.9
1590
53.0
34.5
1590
53.0
34.5
1560
53.0
34.4
1560
53.0
34.4
1560
53.0
34.4
1560
53.5
34.9
036-21315-001 Rev. A (0502)
COOLING
1
SEER + TXV
SEER + TXV
W/O TDR
+ TDR*
-
13.25
-
13.25
-
13.25
-
13.00
-
13.00
-
13.25
COOLING
SEER
SEER
2
W/O TXV
+ TXV
3
-
15.00
-
15.00
-
15.00
-
15.00
-
15.50
-
15.50
-
15.50
-
15.50
-
13.50
-
13.50
-
14.50
-
14.00
-
14.00
-
14.00
-
15.50
-
15.50
-
14.65
-
15.50
-
14.20
-
14.50
-
14.00
-
14.50
-
15.00
-
14.50
-
15.00
-
14.00
-
14.50
-
14.50
-
14.40
-
14.40
-
14.00
-
14.00
-
13.50
-
13.80
-
13.50
-
13.60
-
13.60
-
13.50
-
13.50
-
13.75
-
13.75
-
13.75
-
14.00
EER
12.00
12.00
12.10
11.75
11.90
12.00
EER
13.60
13.60
13.50
13.65
13.75
13.75
13.75
13.90
12.50
12.50
13.35
12.50
12.65
12.70
14.15
14.15
13.05
13.95
12.60
13.10
12.65
12.45
12.80
12.45
12.80
12.30
12.60
12.50
12.50
12.55
12.20
12.20
12.00
12.20
12.2
12.4
12.4
12.4
12.4
12.5
12.5
12.5
12.8
5