A.8 Writable floats
A.8.1 Alarm settings
MODBUS address
Description
40000
Alarm 1 – Trip point
40002
Alarm 2 – Trip point
40004
Alarm 3 – Trip point
40006
Alarm 4 – Trip point
40008
Alarm 5 – Trip point
40010
Alarm 6 – Trip point
40012
Alarm 7 – Trip point
40014
Alarm 8 – Trip point
40016
Alarm 1 – Hysteresis
40018
Alarm 2 – Hysteresis
40020
Alarm 3 – Hysteresis
40022
Alarm 4 – Hysteresis
40024
Alarm 5 – Hysteresis
40026
Alarm 6 – Hysteresis
40028
Alarm 7 – Hysteresis
40030
Alarm 8 – Hysteresis
A.8.2 Analog output settings
see engineering ranges table – Section A.13, page 17.
MODBUS address
Description
40032
Analog output 1 – Electrical range high
40034
Analog output 1 – Electrical range low
40036
Analog output 1 – Engineering range high
40038
Analog output 1 – Engineering range low
40040
Analog output 2 – Electrical range high
40042
Analog output 2 – Electrical range low
40044
Analog output 2 – Engineering range high
40046
Analog output 2 – Engineering range low
40048
Analog output 3 – Electrical range high
40050
Analog output 3 – Electrical range low
40052
Analog output 3 – Engineering range high
40054
Analog output 3 – Engineering range low
40056
Analog output 4 – Electrical range high
40058
Analog output 4 – Electrical range low
40060
Analog output 4 – Engineering range high
40062
Analog output 4 – Engineering range low
40064
Analog output 1 – Failure current
40066
Analog output 2 – Failure current
40068
Analog output 3 – Failure current
40070
Analog output 4 – Failure current
A.8.3 Sensor calibration standards
MODBUS address
Description
40072
COe calibration standard zero
40074
COe calibration standard span
40076
Oxygen calibration standard zero
40078
Oxygen calibration standard span
A.9 Writable 32 bits
A.9.1 Scheduled calibration events
Number of seconds since 01/01/2000.
MODBUS address
41000
41002
A.10 Writable 16 bits
A.10.1 Alarm time hysteresis
Valid range 0 to 9999 seconds.
MODBUS address
42000
42001
42002
42003
42004
42005
42006
42007
42008
42009
42010
42011
42012
42013
42014
42015
42016
42017
42018
Endura AZ40 | Oxygen and carbon monoxide equivalent (COe) analyzer | COM/AZ40/MOD–EN Rev. A
Description
Next scheduled calibration time
Next scheduled blowback time
Description
Zero calibration duration (minutes)
Span calibration duration (minutes)
Calibration recovery duration (seconds)
Damping time (seconds) – 0
Damping time (seconds) – 1
Damping time (seconds) – 2
Damping time (seconds) – 3
Blowback on time (seconds)
Blowback off time (seconds)
Blowback frequency
Blowback recovery duration (seconds)
Alarm 1 – Time hysteresis
Alarm 2 – Time hysteresis
Alarm 3 – Time hysteresis
Alarm 4 – Time hysteresis
Alarm 5 – Time hysteresis
Alarm 6 – Time hysteresis
Alarm 7 – Time hysteresis
Alarm 8 – Time hysteresis