・To reduce the risk of electric shock, make sure
to wait at least 10 minutes after removing the
service plug grip to fully discharge the high
voltage capacitor inside the inverter with
converter assembly.
・Keep the removed service plug grip in your
pocket to prevent other technicians from
accidentally installing it while you are servicing
the vehicle.
NOTICE:
・After removing the service plug grip, turning the power
switch on (READY) may cause a malfunction. Do
not turn the power switch on (READY) unless instructed by the repair manual.
・Do not touch the terminals of the service plug grip.
・If the service plug grip has been struck or dropped, replace it.
HINT:
Waiting for at least 10 minutes is required to discharge the high voltage capacitor inside the
inverter with converter assembly.
While wearing insulated gloves, rotate the handle of the service plug grip and remove the
service plug grip as indicated by the arrows, in the order shown in the illustration.
1
Make other staff aware that a high-voltage system is being dismantled by using the following
sign: CAUTION: HIGH-VOLTAGE. DO NOT TOUCH (see page 19).
2
17
*a
Without waiting for 10
*a
minutes
3