en | 28 | DAS 3000
3.
Repair
---Separator---
3.1
Changing the camera on the edge protection frame
The camera must not be removed from the adapter plate. The camera is mounted on the adapter plate at the
factory and calibrated as an assembly. If the camera is removed from the adapter plate, the calibration is lost
and the camera cannot be used.
---
(1)
1. Remove the front cover
2. Disconnect the USB cable from the defective camera.
(4)
3. Loosen the screws
in the adapter plate.
4. Lift and remove the adapter plate with the defective camera.
5. Position the adapter plate with the new camera on the edge protection frame.
(2)
The guide pins
are located in the positioning holes
(3)
The T-slot nuts
are located in the groove of the profile.
(4)
6. Tighten the screws
in the adapter plate with the new camera.
The T-slot nuts will turn and engage with the profile.
The camera is fastened to the profile.
1
4
3
(1) Adapter plate with camera
(2) Adapter plate guide pins
(3) Hammerhead nuts
(4) Screws
(5) Positioning holes
7. Connect the USB cable to the camera.
8. Attach the front cover to the frame.
---
1 689 975 292 | 2020-05-04
on the frame.
1
4
2 2
3
5 5
2
2
5 5
(5)
on the frame.
Robert Bosch GmbH