Outdoor Fan Control - Fujitsu ASYG07LMCE Service Manual

Split type room air conditioner wall mounted type
Hide thumbs Also See for ASYG07LMCE:
Table of Contents

Advertisement

6. OUTDOOR FAN CONTROL

1. Outdoor Fan Motor
Following table shows the type of the outdoor fan motor. The control method is different
between AC motor and DC motor.
( Table 8 : Type of Motor )
Model
07/09/12/14
2. Fan Speed
( Table 9 : Outdoor fan speed )
Model
07/09
12
14
Refer to Fig.8
( Fig.8 : Outside air temperature zone selection )
Outside air
temperature rises
21°C
12°C
2°C
* The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
* After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as table10 without relating to the compressor frequency.
( Table10 : Outdoor fan speed after the defrost )
07/09/12
14
AC Motor
Zone
Cooling
Y
730/ 650/ 580/ 470
Z
730/ 470/ 250
F
250/ 200/ 150
G
180/ 150
Y
860/ 780/ 720/ 680/ 470
Z
860/ 470/ 330
F
330/ 280/ 230
G
260/ 230/ 200
850/ 750/ 670/ 500
Y
Z
850/ 500/ 380
F
380/ 280/ 250
G
300/ 230/ 200
Outside air
temperature drops
Y zone
19°C
Z zone
10°C
F zone
0°C
G zone
900rpm
950rpm
DC Motor
900/ 760/ 720/ 680/ 470
950/ 850/750/ 670/550/450
01-07
Heating
900/ 650/ 580/ 470
(rpm)
Dry
730/ 470
760/ 470
760/ 470

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asyg09lmceAoyg07lmceAoyg09lmce

Table of Contents