Installation

Installation
Reference numbers and letters in parentheses in
text refer to call-outs in figures and parts drawing.
Always use genuine Graco parts and accessories,
available from your Graco distributor.
Grounding
To reduce the risk of static sparking, ground the pump
and all other components used or located in the
spray/dispensing area. Check your local electrical code
for detailed instructions for your area and type of equip-
ment and be sure to ground all of these components.
Pump: Ground the pump by connecting a grounding
wire (12 ga minimum) from the pump's grounding
lug to a true earth ground.
4
Air compressor and hydraulic power supply: Ground
according to local code and manufacturer's recom-
mendations.
Fluid hoses: Use only grounded hoses with a maxi-
mum of 500 feet (150 m) combined hose length to
ensure grounding continuity.
Dispensing valve: Obtain grounding through con-
nection to a properly grounded fluid hose and pump.
Fluid supply container: According to local code.
Object being sprayed: According to local code.
All solvent pails used when flushing, according to
local code. Only use metal pails which are conduc-
tive. Do not place the pail on a non-conductive sur-
face, such as paper or cardboard, which interrupts
the grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
gun firmly to the side of a grounded metal waste
container, then trigger the gun.
308124H