Download Print this page

Graco A Series Instructions-Parts List Manual page 9

4-ball lowers
Hide thumbs Also See for A Series:

Advertisement

Lower
Reassembly
1. See F
. 4. Place the halves of the piston (10)
IG
around the packing (11) and snap them together.
2. Apply high strength (red) Loctite
entire length of the piston rod (17) threads. Sealant
must be allowed to cure for a minimum of 12 hours
before use. Screw the rod through the piston and
spacer (44) and into the piston nut (12). Torque the
nut to 95-100 ft-lb (129-135 N•m).
3. With the inlet housing (15) turned upside down,
install the balls (5) and the gaskets (7*).
COMPONENT RUPTURE HAZARD
The relief valve seat (6) must be installed at the fluid
inlet, as shown in F
. 6. The relief valve reduces the
IG
risk of pump over pressurization. The seat cannot
relieve pressure if installed on the other side of the
inlet housing.
4. Install the relief valve inlet seat (6) in the left side of
the inlet housing (15), as viewed in F
into the inlet housing identifies the correct location
for the relief valve seat.) The pin (P) on the seat
must point into the housing. The pin limits the posi-
3A2023C
®
263 or 2760 to
. 6. (Text cast
IG
F
is shown as the back of this illustration)
5. Install the inlet seat without a relief valve (33) in the
NOTE: The inlet seats (6 and 33) are not reversible; the
chamfered side must face the ball.
6. Place the inlet manifold (18) on the inlet housing
7. Place the inlet manifold (18) in a vise. Place one
Repair - Models 24J088 and 24J089 Only
tioning of the seat, ensuring that the vent is not
blocked by part of the housing. See F
7
6
c
. 6. Inlet Seat with Pressure Relief Valve (Left side
IG
right side of the inlet housing (15).
(15). Apply removable (blue) Loctite
length of the screw (9) threads. Install the lockwash-
ers (8) and screws (9), and torque to 25-30 ft-lb
(34-40 N•m).
o-ring (2*) in each side of the inlet housing (15),
where the tubes (3) sit. Place o-rings (2*) in the
grooves at each end of the tubes. Place a gasket (4)
in both the inlet and outlet housing (15 and 16).
Position the tubes and cylinder (1) in the inlet hous-
ing.
. 6.
IG
a
b
P
®
243 to entire
9

Advertisement

loading

This manual is also suitable for:

24j08824j08924j090