Troubleshooting Chart
Symptom
Furnace fails to operate
Furnace fails to operate
LED Status
Fault Description
Aux limit switch open (blower
EED
compartment)
Aux switch (condensate switch)
EEF
open
Check filters and ductwork for blockage, clean
filters or remove obstruction
Check circulator blower speed and performance,
correct speed or replace blower motor if
necessary
Tighten or correct wiring connection
Check evaporator drain pan, trap, piping
49
Corrective Actions