AE00111
OIL WARNING SYSTEM
When the oil level falls below the lower level, the
engine stops automatically. Unless you refill with oil,
the engine will not start again.
NOTE:
If the engine stalls or does not start, turn the engine
switch to "ON" position and then pull the recoil starter.
If the oil warning light flickers for a few seconds, the
engine oil is insufficient. Add oil and restart.
700-027c
AE00122
ENGINE SWITCH
The engine switch controls the ignition system.
1
Ignition circuit is switched on.
The engine can be started.
2
763-084f
Ignition circuit is switched off.
The engine will not run.
ON
AE00131
AC SWITCH (N.F.B.)
The AC switch (Non-Fuse Breaker) turns off automati-
cally when the load exceeds the generator rated out-
OFF
put.
763-095
1
2
ON
cC
Reduce the load to the specified generator rated
OFF
output if the AC switch (N.F.B.) turns off. If it turns
763-086c
off again, consult your Yamaha dealer.