General Information; Cabinet Requirements; Countertop Requirements - Bosch RGM8058UC Installation Manual

Gas rangetop
Hide thumbs Also See for RGM8058UC:
Table of Contents

Advertisement

Available languages

Available languages

General Information

30":
36":

Cabinet Requirements

The minimum spaces that must be maintained when
installing the gas cooktop shall be:
30": minimum 30" (762 mm)
A
36": minimum 36" (914 mm)
minimum 20" (508 mm)*
B
minimum 30" (762 mm) clearance between
C
the top of the cooking surface and the
bottom of the unprotected wood or metal
cabinet
30": minimum 30" (762 mm)
D
36": minimum 36" (914 mm)
minimum 24" (610 mm)
E
maximum 13" (330 mm)
F
minimum 20" (508 mm)*
G
7 3/8" (187 mm)
H
minimum 4" (102 mm)
I
minimum 12" (305 mm)
J
minimum 0" (0 mm)
K
* Minimum distance is 12" (305 mm), but the total
distance, left plus right, must be minimum 40"
(1016 mm).
Gas supply line and grounded outlet
X = Gas Supply Line
Y = Grounded Outlet
The positions of the gas supply line and the grounded
outlet should be:
8-12" (203-305 mm)
L
2-4" (51-101 mm)
M
24-28" (610-711 mm)
N
24-28" (610-711 mm)
O

Countertop Requirements

WARNING
9
To reduce the risk of ignition of surrounding
combustible materials, install at least 20" (508 mm)
from both sidewalls. Minimum distance is 12"
(305 mm), but the total distance, left plus right, must
be minimum 40" (1016 mm).
The countertop must be level and horizontal. The stability
of the countertop must be maintained after the cut-out
has been made.
7