Refrigerant Spec Sheet - Hussmann SHVSV Series User Manual

Bakery service merchandiser
Table of Contents

Advertisement

Refrigeration Spec Sheets
13 1/4"
51 3/4"
20 1/4"
15"
5 1/8"
2"
REFRIGERATION DATA:
CASE LENGTHS/
CASE USAGE
WEDGES
BAKERY
3',4',5',6',8',10',12'
45° IS
BAKERY
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
REFRIGERATION DATA CONTINUED:
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
CUT IN
USAGE
(ºF)
BAKERY
26
ELECTRICAL DATA:
EVAPORATOR FANS,
CASE LENGTH
# OF
EVAP
FANS
3'
3
4'
3
5'
4
6'
6
8'
6
10'
8
12'
9
45° IS
4
CANOPY
LIGHTS
CASE LENGTH
H.O. LED
AMPS WATTS
3'
0.32
4'
0.41
5'
N/A
6'
0.64
8'
0.82
10'
N/A
12'
1.23
45° IS
N/A
BAKERY SERVICE VERTICAL GLASS WITH DRAWER
HUSSMANN - SHVSV-DWR (CHINO)
22"
24"
10"
29 1/2"
26"
26"
9 7/8"
CLEAR
30 1/4"
SLIDE-OUT DECK
+3" RAISED BASE
36 3/8"
38 3/8"
*DRAWER LOAD RATING: 30 LB/FT
CAPACITY ***
TEMPERATURE (ºF)
(BTU/HR/FT) (TOTAL
FOR WEDGES)
RATING CONDITION EVAPORATOR
NSF 7
AHRI 1200
NSF 7
450
450
20
2900
2900
20
1) BTU'S DO NOT INCLUDE LIGHTS
2) ADD 10 BTU'S PER FOOT/PER SHELF ROW FOR OPTIONAL LED SHELF LIGHTS
3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
DEFROST
DEFROST
TIME
FREQUENCY
CUT
TYPE
(MIN)
OUT
(#/DAY)
(ºF)
23
OFF TIME
40
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
AIRSWEEP FANS,
4.7" AXIAL FAN
4.7" AXIAL FAN
# OF
AMPS
WATTS
AMPS WATTS
FANS
0.12
14
2
0.08
0.12
14
2
0.08
0.16
19
2
0.08
0.25
28
4
0.16
0.25
28
4
0.16
0.33
38
4
0.16
0.37
42
6
0.25
0.16
19
2
0.08
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
OPTIONAL SHELF
MAX. H.O. LED
H.O LED
LOAD
AMPS
WATTS
AMPS WATTS
37
0.29
34
0.61
47
0.35
41
0.76
N/A
N/A
N/A
N/A
73
0.59
67
1.22
94
0.71
81
1.53
N/A
N/A
N/A
N/A
141
1.06
122
2.29
N/A
N/A
N/A
N/A
REAR OF CASE (SERVER SIDE)
3 1/2"
3 1/2"
3 1/8"
1 3/8"
ELECT
C
REFRIG.
20"
L
6"
GFCI
RECEPTACLES
(OPTIONAL)
38 1/2"
DRAIN
SHVSV-DWR-3-R
FRONT
CLOSE-OFF
FRONT OF CASE (CUSTOMER SIDE)
1 1/8"
36"
VELOCITY
(FT/MIN)
DISCHARGE
AIR ** (°F)
AHRI
NSF 7
NSF 7
1200
24~26
250~300
20
25~27
250~300
20
TERM.
DEFROST
DRIP
TEMP
WATER
(°F) COIL
TIME
(LBS/DAY/FT)
ONLY
6
45
NA
0.75~1
OPTIONAL
CANOPY
LED SHELF
LIGHTS LED
LIGHTS
AMPS WATTS
AMPS
WATTS AMPS WATTS
9
0.24
27
0.20
23
9
0.32
37
0.27
31
9
0.41
47
0.34
39
19
0.47
54
0.40
46
19
0.65
74
0.54
62
19
0.82
94
0.68
78
28
0.97
112
0.81
93
9
0.32
37
0.26
29
70
88
N/A
141
176
N/A
264
N/A
17
8"
1 3/8"
4"
39 7/8"
3 1/8"
20"
1 1/8"
L C
Drain
6"
4 1/8"
SHVSV-DWR-45I-R
EFR #1338
2"
EST.
REFG.
CASE
LENGTHS
CHRG.
(LBS)
3'
0.3
4'
0.5
5'
0.7
6'
0.9
8'
1.1
10'
1.4
12'
1.6
45° IS
0.5
END PANEL WIDTH KEY
END PNL
# OF END
WIDTH
PNLS
(IN.)
1
1.125
2
1.125
MAX. LED LOAD
HEATERS
(W/ ALL OPTIONS)
AMPS
WATTS
OUTLETS
0.44
50
0.87
100
0.59
68
1.04
120
0.75
86
1.09
125
0.87
100
1.57
180
1.18
136
2.09
240
1.49
172
2.63
303
1.78
204
3.13
360
0.57
66
0.65
75
DRAWERS
CASE
NUMBER OF
LENGTH
DRAWERS
3'
1
4'
1
1
5'
2
6'
8'
2
10'
2
12'
3
2
45° IS
REVISION DATE 03/05/18
39 7/8"
8"
Refrig
4"
38 1/2"
20°F GLYCOL
6° RISE
GPM
PSI
0.5
1.2
0.7
2.0
0.9
3.0
1.0
1.4
1.4
1.5
1.7
1.4
2.0
1.2
1.1
1.3
TOTAL ADDED
LENGTH (IN.)
1.125
2.25
CONVENIENCE
OUTLETS (OPTIONAL)
#
VOLTS AMPS
1
115
15
1
115
15
1
115
15
1
115
15
1
115
15
1
115
15
2
115
30
N/A
N/A
N/A