CUSTOM MODE
When MODE indicator: CUST (yellow) lights up, response
time setting, data bank loading (only one unit), or code set-
ting can be displayed. Setting contents of the displayed item
can be changed. For the setting procedure, refer to <PRO
5: CUSTOM setting> in "
PRO MODE."
14
For setting of each item, refer to the following table.
Item
Display display
Response time setting
Data bank loading (Only
one unit)
Code setting
14
PRO MODE
When MODE indicator: PRO (yellow) lights up, PRO mode can be set.
The mode will change to RUN mode when the MODE key is held down during this
setting process. However, changed items before holding down the mode selection
key have been set.
Jog switch
MODE key
3UHVV &RQ¿UP VHWWLQJ FRQWHQWV
Cancel during setting
Turn: Select setting items
Response
PRO mode
PRO 1
time setting
Press
Press
Hysteresis
setting
Turn
Digital dis-
PRO 2
play setting
Press
Eco setting
Time period
hold setting
Turn
Display
adjustment
Data bank
PRO 3
loading
Press
Data bank
saving
Turn
PRO 4
Copy setting
Press
Communication en-
able / disable setting
Turn
Communication
protocol setting
PRO 5
Code setting
Press
Reset setting
Turn
CUSTOM
setting
PRO 1
Jog switch
Press: Confirm setting
Turn: Select setting
Reference item
<PRO 1: Response time setting>
<PRO 3: Data bank loading>
<PRO 5: Code setting>
Symbol explanation
Press : Press down the jog switch
Turn : Turn the jog switch
Automatic : Automatically move to next
1ms
Press
Turn
Standard
Press
Lock OFF
Press
Turn
Eco OFF
Press
Turn
Hold OFF
Press
Turn
Display ad-
justment OFF
Press
1 unit only
1ch
Press
Press
Turn
All units
1ch
Press
Turn
Automatic
1 unit only
1ch
Press
Press
Turn
All units
1ch
Press
Automatic
YES
Press
Press
(2 cycles)
Turn
Automatic
Communica-
tion enable
Press
Turn
Communica-
tion mode
Press
Jog switch
Press
3UHVV &RQ¿UPHG
Turn: Select code, shift decimal point
Turn
Press
Press
Turn
Response
time setting
Press
Response time
setting
contents
Hysteresis setting
items
Digital display
setting
Eco setting
Time period hold
setting
Display adjustment
Data bank loading
Data bank saving
Copy setting
Communication en-
able / disable setting
Communication
protocol setting
YES
Press
Code setting
Press
Press
Reset setting
good
CUSTOM setting
YES
Press
Code setting table
Press
Press
*UHHQ GLJLWDO GLVSOD\ ULJKW VLGH LV WKH ¿UVW GLJLW
good
4th digit
NO / NC mode
Automatic
NO / NO
good
NC / NO
NO / NC
NC / NC
Automatic
RUN mode
5HG GLJLWDO GLVSOD\ ULJKW VLGH LV WKH ¿UVW GLJLW
Communication
protocol setting
Communication
mode
Communication
halt
Communication
mode
Communication
halt
Item
Default setting
Sets response time.
"
´  V ³
"
": 10ms, "
Hysteresis can be set when EASY mode or window comparator mode is set.
"
": Small
"
": Standard
"
": Large
When setting to "
RUN mode, pressure value and peak / bottom value can be switched to
show on the digital display (red).
"
": Lock OFF
"
": Lock ON
Power consumption can be lowered.
"
": Eco OFF
"
": Eco ON
If any key operation is not carried out for 20 sec. in RUN mode,
the digital display turns OFF.
"
": Manual
The digital display turns OFF when setting the key lock function
to ON in RUN mode.
"
": FULL
The digital display turns OFF if any key operation is not carried
out for 20 sec. or the key lock function is set to ON in RUN mode.
"
": Hold OFF
Peak / bottom value in the digital display refreshing condition
can be displayed.
"
": Hold ON
Peak / bottom value in the hold condition can be displayed.
Forcibly sets the pressure value indicated on the digital display to "zero."
Threshold value changes in conjunction with the pressure value.
"
": Display adjustment OFF
"
": Display adjustment ON
/RDGV FRQ¿JXUDWLRQ VHWWLQJ IURP WKH GDWD EDQN
"
": Select this mode when only one unit to load.
"
": Select this mode when all units to load in a lump by optical com-
munications. For optical communications, refer to "
COMMUNICATIONS."
"
": 1ch
"
": 2ch
"
": 3ch
6DYHV FRQ¿JXUDWLRQ VHWWLQJ IURP WKH GDWD EDQN
"
": Select this mode when only one unit to save.
"
": Select this mode when all units to save in a lump by optical com-
munications. For optical communications, refer to "
COMMUNICATIONS."
"
": 1ch
"
": 2ch
"
": 3ch
The set contents can be copied to all sub controllers cascaded to the right
side from the connector side of the main controller by optical communica-
-
tion. However, the data bank loading / saving, and zero-adjustment set-
tings are excluded.
For optical communications, refer to "
When conducting the copy setting or data bank loading / saving from the main con-
troller via optical communications, it is possible that only the sub controller which is
set to communication disable "
"
": Communication enable
"
": Communication disable
When conducting the copy setting or data bank loading / saving from the main
controller via optical communications, it is possible that only the sub controller
which is set to communication halt "
"
": Communication mode
"
": Communication halt
Consistent setting can be done by inputting 8-digit code instead of inde-
SHQGHQW VHWWLQJ ,Q DGGLWLRQ SUHVHQW VHWWLQJ FDQ EH FRQ¿UPHG
-
If setting to "
", returns to default settings (factory settings).
Selects an item in CUSTOM mode to display.
"
": Response time setting
"
": Data bank loading
"
": Code setting
3rd digit
Response time setting
Digital display
 V
Pressure value
 V
Peak / bottom value
1ms
Pressure value
5ms
Peak / bottom value
-
10ms
-
-
50ms
-
-
100ms
-
-
500ms
-
-
-
-
4th digit
3rd digit
Communication en-
CUSTOM mode
able / disable setting
Response time
setting
Communication
enable
Data bank loading
Code setting
Communication
disable
-
Window comparator
-
-
-
mode
-
-
-
-
-
-
Forced ON output
-
-
-
mode
Forced OFF output
-
-
-
mode
Description
´  V ³
": 1ms, "
": 5ms
": 50ms, "
": 100ms, "
": 500ms
" (lock OFF) and pressing the jog switch in
OPTICAL
16
16
OPTICAL
16
OPTICAL COMMUNICATIONS."
", not to receive the set contents.
", not to receive the set contents.
2nd digit
1st digit
Digital display setting
Eco setting
Eco OFF
Lock OFF
Eco ON
Manual
Lock ON
FULL
-
-
-
-
-
-
-
-
-
-
2nd digit
1st digit
Comparative
Comparative
Hysteresis setting
output 1 mode
output 2 mode
H-01
EASY mode
EASY mode
H-02
Hysteresis mode
Forced ON output
H-03
mode
Forced OFF output
H-01
mode
H-02
-
H-03
-
Hysteresis mode
-
-
-
-
-
-