Yamaha DRCX User Manual page 39

Yamaha network board user's manual
Hide thumbs Also See for DRCX:
Table of Contents

Advertisement

No.
Symptom
Probable causes
7)
8)
Cannot make
1)
2
TELNET
connection or
cannot
terminate the
2)
TELNET
connection
right away.
(ping reply is
3)
normal).
4)
5)
6)
An OK does
1)
3
not come
back after
login, or no
replay comes
back even
2)
after issuing a
command.
(Some unit
control
3)
commands
are useable
such as
LOGOUT or
BYE.)
Wrong IP
• Check the settings after referring to "2-
address, subnet
4-2 Setting the IP address" p. 10, "2-4-
mask or gateway
3 Setting the subnet mask" p. 12, and
settings on
"2-4-4 Setting the gateway" p. 13.
controller.
Ethernet unit is
• Try substituting the Ethernet unit.
defective
Wrong IP
• Check that the IP address of the
address used
controller you are attempting to
during Telnet
connect with is correct.
connection
Wrong Port No.
• Check that the port No. of the
used during
controller you are attempting to
TELNET
connect with is correct.
connection.
The controller is
• When connected, the message "telnet is
already logged in
already used!" appears.
with another
TELNET
terminal.
Alarm issued to
• Alarm message appears when
controller.
connected.
• Connect the TPB and check for an
alarm.
• Status led is lit up in red.
IP address is the
• Check if the IP address and MAC
same as another
address have a correct match by using
network device.
the "arp" command incorporated in the
OS.
• Check all devices on the network to
find if the same IP address is being
used.
Network traffic
• Check if the traffic load is appropriate.
(communication
data load) is too
heavy.
Ethernet unit is
• See "2-4-1 Enabling the Ethernet Unit"
not enabled and
(p. 9) and check if the Ethernet Unit is
not identified
enabled.
(recognized) by
controller.
I/O custom
• Check the I/O signal (Check on the
command input
sequencer monitor, etc.)
signal is set ON.
• Communication error is issued when
TPB is connected to controller.
Commands such
• Reply comes back after axis movement
as origin return,
or writing data.
axis movement
commands, or
data write
commands are
being run from
I/O or RS/232C.
Checkpoints
33
CHAPTER2 Ethernet Unit
Action
• Redo the IP address, subnet mask and
gateway settings correctly. Then turn
on the controller power again.
• If operation returns to normal, then the
Ethernet unit is probably defective, so
replace the Ethernet unit.
• Enter the correct IP address.
• Enter the correct IP address.
• Await termination of current TELNET
connection.
• Troubleshoot according to the type of
alarm.
• If the IP address and MAC address do
not match each other, then the IP
address is wrong, so try redoing the
settings.
• If found to be the same as another
device, change the setting.
• Change the network structure to get a
smaller traffic load.
• Enable the Ethernet unit and turn on
the power to the controller again.
• Always use a pulse input for the
custom command input.
• When issuing TELNET commands, do
not run commands from the I/O or RS-
232C.