Download Print this page

Technical Data - Kärcher IVS 100/40 Original Operating Instructions

Hide thumbs Also See for IVS 100/40:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
The motor (suction turbine) does not
start running
No electrical voltage present
 Check the socket and the power supply
fuse.
 Check the mains cable and the mains
plug of the device.
 Check all parts for clogging.
 Check the fit of all electrical connections.
No vacuuming operations, airflow es-
capes from the suction hose.
Suction turbine rotating in the wrong direc-
tion
 Swap the pins on the plug.
Electrical connection
Mains voltage
Power frequency
Protection type
Protection class
Maximum permissible mains grid im-
pedance
Nominal power
Fuse protection
Characteristic of the fuse
Dimensions and weights
Typical operating weight
Length x width x height
Device performance data
Container capacity
Air volume
Vacuum with pressure-limiting valve kPa
Suction power slowly reduces
Filter, nozzle, suction hose or suction pipe
clogged.
 Check the accessory for clogging.
 Clean the accessory if necessary.
 Clean the filter.
 Replace the filter if necessary.
Escaping dust when vacuuming
Filter not correctly fastened or faulty.
 Clean the filter and insert it correctly.
 Check the filter for faults and replace if
necessary.
Customer Service department
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.

Technical data

IVS 100/40
V
380 - 480
Hz
3~ 60
IPX4
I
Ω
0.400+j0.250 0.400+j0.250 0.400+j0.250
W
4800
A
16
B/C
kg
142
mm
1202 x 686 x
1465
l
100
l/s
166
15.0
(mbar)
English
IVS 100/55
IVS 100/75
380 - 480
380 - 480
3~ 60
3~ 60
IPX4
IPX4
I
I
6600
9000
16
32
C
B/C
145
160
1202 x 686 x
1202 x 686 x
1465
1465
100
100
166
179
21.0
32.5
13

Advertisement

loading

This manual is also suitable for:

Ivs 100/55Ivs 100/75Ivs 100/55 60