Download Print this page

Initial Startup; Permissible Mains Grid Impedance; Operation - Kärcher IVS 100/40 Original Operating Instructions

Hide thumbs Also See for IVS 100/40:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
On/Off switch
1
Green indicator lamp (IVS 100/55 and
2
IVS 100/75 only)
"Switch on device" button (IVS 100/
3
55and IVS 100/75 only)
Steering rollers with parking brake
4
Muffler
5
Filter chamber lock
6
Filter chamber lid
7
Filter cleaning handle
8
Pressure gauge
9
Sliding handle
10
Suction pipe holder
11
Hose holder
12
Suction hose connection nozzle
13
Vacuum cleaner waste container un-
14
locking lever
Floor nozzle holder
15
Remote control
Using the wireless remote control
The appliances:
 IVS 100/55
 IVS 100/75
are equipped with a radio receiver for the
optionally available wireless remote con-
trol.
ATTENTION
Operation with a wireless remote con-
trol
Teaching and operation of the device using
the wireless remote control are described in
the operating instructions provided with the
remote control.
WARNING
Risk of damage
Read the operating instructions and all
safety instructions provided before using
the wireless remote control.
Indicator lamps
Green
 Blink codes for teaching the remote
control (IVS 100/55 and IVS 100/75).
 Lights up when the suction turbine is
running.
10

Initial startup

1. Bring the device into the working posi-
tion and secure with the parking brake if
necessary.
2. Insert the suction hose into the suction
hose connection.
3. Plug the desired accessory onto the suc-
tion hose.
4. Ensure that vacuum cleaner waste con-
tainer is inserted correctly.
Permissible mains grid
DANGER
Warning
The maximum permissible mains grid im-
pedance at the electrical connection point
(see technical data) must not be exceeded.
Contact your electricity supplier in the case
of any uncertainties regarding the mains
grid impedance at your electrical connec-
tion point.
Switching on the IVS 100/40 device
1. Connect the mains plug.
2. Switch on the device at the main switch.
Switching on the IVS 100/55 and IVS
100/75 devices
1. Connect the mains plug.
2. Switch on the device at the main switch.
3. Press the "Switch-on device" button.
Vacuuming process
1. Perform vacuuming.
2. Regularly check the filling level in the dirt
receptacle, since the device does not
switch off automatically.
3. Empty the vacuum cleaner waste con-
tainer as necessary.
4. Clean or replace the filter as necessary.
Cleaning the filter
A pressure gauge showing the vacuum in-
side the device is mounted on the front of
the device.
IVS 100/40 60 Hz
1 Switch off the device at the"ON/IFF
switch".
2 Move the filter cleaning lever back and
forth several times.
English
impedance