1. Press *.
2. Enter the 6 digit master code (for the first use, the master code default is 000000).
3. Press * or present the Master Card.6 audible beeps are emitted and the LED flashes green and red to confirm
entry into programming mode.
4. Press 5, then * to enter into the entry mode menu. 1 audible beep is emitted and the LED flashes green.
5. To program an entry mode press 0 for Card and PIN code. Press 1 for Card only or press 2 for Card or PIN code.
6. Press * to confirm. 1 audible beep is emitted and the LED flashes green and red.
7. Press # to exit from the programming mode. 6 beeps confirm the reader is in standby mode.
8.
*
5
Program Alarm Time Delay
1. Press *.
2. Enter the 6 digit master code (for the first use, the master code default is 000000).
3. Press * or present the Master Card.6 audible beeps are emitted and the LED flashes green and red to confirm
entry into programming mode.
4. Press 6, then * to enter into the alarm time delay menu. 1 audible beep is emitted and the LED flashes green.
5. To program the alarm time delay, enter the 2 digit number from 01 to 99. The number is multiplied by 10
seconds. 01 equals 10 seconds and 99 equals 990 seconds. Enter 00 to turn off the alarm.
6. Press * to confirm. 1 audible beep is emitted and the LED flashes green and red.
7. Press # to exit from the programming mode. 6 beeps confirm the reader is in standby mode.
*
6
Cancel Single Card and PIN code (using card or card code)
1. Press *.
2. Enter the 6 digit master code (for the first use, the master code default is 000000).
3. Press * or present the Master Card.6 audible beeps are emitted and the LED flashes green and red to confirm
entry into programming mode.
4. Press 7, then * to enter into the cancel single card and PIN code menu. 1 audible beep is emitted and the LED
flashes green.
 
 
 
1 Beep
Green
LED
flashing
0 Card and Pin
1 Card only
2 Card or Pin
1 Beep
Green
LED
flashing
Alarm time delay 2 digit 00-99
5502 Timberlea Blvd.,
Mississauga, ON Canada L4W 2T7
CV-500PPK-V.2
*
*
www.camdencontrols.com
Toll Free: 1.877.226.3369
Installation Instructions
1 Beep Green
and RED LED
flashing
#
1 Beep Green
and RED LED
flashing
#
File: CV-500PPK-V.2_NF-Man_Rev1.doc
Revised: March 8, 2011
Part No.: 40-82B131
 

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents