User Menu Map - Xantrex 120 VAC/60 Owner's Manual

Sw series inverter/chargers
Table of Contents

Advertisement

MENU SYSTEM

USER MENU MAP

The values shown are the factory default values for
Menu Heading
Model SW2512.
See the USER and SETUP menu item descriptions
Menu Item
Setpoint
for default values for other models.
Information
Inverter Mode
Generator Mode
1
Set Inverter
Set Generator
OFF SRCH
ON CHG
OFF AUTO
CHG avail. Only
Gen under/over
in FLT mode.
speed
Press red or
Generator start
setpoint button
error
Generator sync
to move.
error
Move cursor to
Inverter OFF to
Gen max run time
resetOverCurrent
error
Load Amp Start
Ready
Voltage Start
Ready
Exercise Start
Ready
Move cursor to
GEN OFF to reset
Generator error.
If no start in 5
trys then error.
If Gen starts &
runs for 5 min
then stops the
inverter will
not attempt
restart until
gen auto start
conditions are
again satisfied.
If Gen runs for
More than max
Run time then
Error.
Under/Over speed
Will cause a
Sync error in 10
minutes
2001 Xantrex Technology, Inc.
Page
5916 - 195th Street N. E.
34
Arlington, WA 98223
MENU HEADINGS
Trace
Meters
2
Engineering
3
Press reset now
Inverter/charger
ON
EQ
for defaults
Amps AC
Revision 4.01
Input amps AC
NO
5916 195th St NE
Load
NO
Arlington, WA
amps AC
98223 USA
Battery actual
NO
volts DC
Ph
360-435-8826
Battery TempComp
NO
Fax 360-435-2229
volts DC
Inverter
NO
volts AC
Grid (AC1)
NO
volts AC
Generator (AC2)
NO
volts AC
Read Frequency
Hertz
AC1 & AC2 volts
valid only when
inverter synced
to that input.
Batt volt actual
is used for
LBCO,HBCO,LBX,
LBCI,sell volts,
and gen starting
Batt volt temp
comp is used,
for float, bulk, eq
& aux relays
Push buttons on
Control Panel
Error Causes
4
Over Current
00
NO
Transformer
00
overtemp
NO
Heatsink
00
overtemp
NO
High Battery
12.6
voltage
NO
Low Battery
12.6
voltage
NO
Inverter breaker
00
tripped
NO
AC source wired
00
to output
NO
External error
00
(stacked)
NO
Generator start
60
error
NO
Generator sync
error
NO
Gen max run time
error
NO
Gen under/over
speed
NO
Inverter breaker
tripped
NO
Telephone: 360/435-8826
Fax: 360/435-2229
www.traceengineering.com
Time of Day
5
00:00:00
6
Set Clock hour
00:00:00
Set Clock minute
00:00:00
Set Clock second
00
Generator Timer
7
Start Quiet
Time
h:m
08:00
End Quiet
Time
h:m
08:00
Gen doesn't run
During quiet
time unless batt
volts is less.
than LBCO volts
for 30 seconds.
To defeat timers
set start = end.
If exercise day
set to 1 then
gen will always
start @ endquiet
End User Menu
8
SW Series Inverter/Charger
Part No. 2031-5
Rev. C: February 2001