RMS EXAMPLE: CONFIGURING THE
MPS-488HP IN THE CONTROL SOFTWARE
To configure the MPS-488HP in the Control Software:
1. Power on the MPS-488HP and RMServer(s).
2. Connect Compass and RMServer to the same local area
network (LAN).
3. In Compass, click the RMServer > Inventory tab.
4. In the Device list, right-click the MPS-488HP powering
the Ashby loudspeakers and choose Edit Loudspeaker
Inventory.
5. In the Edit Loudspeaker Inventory dialog box, click in the
Product column and select the Ashby loudspeaker model
connected to each MPS-488HP channel output.
Figure 5: Edit Loudspeaker Inventory dialog in Compass
6. Enter a name and the number of loudspeakers looped on
each channel.
7. Click OK to save and upload the MPS-488HP loud-
speaker inventory.
Once the MPS-488HP is added to an RMS page, the
device container can display channel labels with simple
device status or a full meter bar display along with a
detailed text view showing voltage and current draw for
the connected Ashby loudspeakers.
Figure 6: Voltage and current draw for connected loudspeakers in
Compass
CAUTION:
Disconnect the mains plug or power
off the MPS-488HP before disconnecting its
power cord.