NEC ASPILA EX Feature Manual page 1045

Hide thumbs Also See for ASPILA EX:
Table of Contents

Advertisement

Alarm
Type
Report
5
0
6
0
7
1 (MAJ)
8
1 (MAJ)
9
0
10
0
11
0
12
0
13
0
:
:
30
2 (MIN)
31
0
:
:
35
0
36
0
37
0
38
0
39
0
40
0
41
0
:
:
Aspila EX Software Manual
Program 90 : Maintenance Program
Note
0
Download Error
0
-- Not Used --
0
Power Failure
0
RAM Backup Battery
Error
0
Blocking (No default
setting)
0
ISDN
0
CTI
0
ACD
0
-- Not Used --
:
:
0
SMDR Buffer Full
0
:
:
0
CS Blocking
0
CS Error Information 1
0
CS Transmission Error
0
CSIU Dch Error
0
CSIU Transmission
Error
0
CS Error Information 2
0
:
90-10 : System Alarm Setup
Is Used To
Advise of . . .
Download may have failed
because the PCB is blocked
(disabled) or the sub-pro-
gram does not exist on the
system flash card.
System power supply may
be defective or commercial
power is off.
RAM backup battery on the
CPRU PCB is unplugged or
defective.
Failure may have occurred
because:
Terminal blocking
detected.
Terminal is unplugged.
Wire is disconnected.
DSTU card is defective.
The SMDR buffer is full.
Action
After unblocking the PCB, if
RECover message is received
in the alarm report, it is cor-
rected. If not, then replace the
system flash card.
Check the system AC switch,
fuse and AC outlet. If still faulty,
replace the power supply.
Check the battery connector. If
it is connected correctly, then
replace the battery.
Check the terminal wiring and
reconnect properly. Then
unplug and plug in the PCB. If
RECover message is received
in the alarm report, it is correct.
If not, replace the PCB and/or
terminal.
Check the printer for the
SMDR.
Programming
1039