Download Print this page

Wolf PL582212 Specifications page 7

Pro ventilation hood liner
Hide thumbs Also See for PL582212:

Advertisement

Planning Information
Pro Ventilation Hood Liner
M O D E L P L 5 8 2 2 1 2
W O L F B L O W E R A S S E M B L I E S
A ventilation system must include a blower
assembly. Wolf ventilation hood liners are
shipped without the blower assembly. An
internal, in-line or remote blower assembly must
be selected to accommodate the cooking appli-
ance, CFM requirements and homeowner prefer-
ences. Internal, in-line and remote blower assem-
blies are available as sales accessories through
your Wolf dealer.
IMPORTANT NOTE: Use only a Wolf blower
with all Wolf ventilation products.
7 /8
24
"
(632)
18"
12"
(457)
(305)
8"
(203)
22"
18"
(559)
(457)
In-line BLOWER-110IL
3 /4
20
"
(527)
1 /4
28
"
(718)
10"
(254)
Diameter
1 /2
15
"
(394)
1 /2
24
"
(622)
14"
(356)
3 /4
4
3 /4
(121)
24
"
(629)
Remote BLOWER-90REM
Unit dimensions may vary by ±
Dimensions in parentheses are in
millimeters unless otherwise specified.
1 /2
29
"
(749)
10"
(254)
Diameter
3 /4
14
"
(375)
1 /8
10
"
(257)
"
22"
(559)
Remote BLOWER-120REM
1
/
" (3).
8
Internal blowers are mounted inside the hood
liner canopy. In-line blowers are mounted in
between the hood liner and the exterior of the
home. Remote blowers can be mounted on the
roof or in some cases, on an exterior wall. Refer
to the illustrations below for dimensions of Wolf
in-line and remote blowers.
Pro ventilation recommendation charts on the
following page provide minimum CFM recom-
mendations according to the cooking appliance
and hood liner used and blower options for each
specific Pro hood liner.
18"
(457)
10"
(254)
1 /2
29
"
(749)
3 /4
14
"
1 /2
29
"
(375)
(749)
7
1 /4
"
(184)
Remote BLOWER-150REM
21"
(533)
10"
(254)
10"
(254)
Diameter
1 /2
29
"
(749)
3 /8
10
"
(264)
7
1 /4
25"
"
(635)
(184)
7

Advertisement

loading