Accessories; 6 English - Windsor Sweeper RRB 360 Operator's Manual

Windsor sweeper operators manual
Table of Contents

Advertisement

Available languages

Available languages

Check tension, wear and damages on
the V-belt of the sweep roller drive.
Check suction blower
Check hose at the suction blower for
tightness.
Replacing the fuse
1 Automotive flat plug fuse
2 Pole fuse
– Replace the automotive flat plug fuse
with the following rating: 1 A (F2) - vac-
uum pump
Replace defective fuse.
Pole fuse
Replace defective fuse.
Note
A defective pole fuse may only be replaced
by a Windsor service technician or an au-
thorised expert. If this fuse is defective,
check the usage conditions and the entire
control system.
16
English

Accessories

Side brushes
6.905-626.0
With standard bristles for indoor and out-
door areas.
Standard sweep roll-
4.762-430.0
er
Resistant of wear and moisture. Univer-
sal bristles for inside and outside clean-
ing.
Roller-brush, soft
4.762-442.0
With natural bristles especially for fine
dust sweeping on smooth indoor floors.
Not resistant to wetness; not for abrasive
surfaces.
Dust filter
6.414-576.0
Roller brush, anti-
4.762-441.0
static
Carpet sweeping unit 2.641-665.0